A cardiovascular monitoring system used in conscious cynomolgus monkeys for regulatory safety pharmacology. Part 2: Pharmacological validation

Affiliations

A cardiovascular monitoring system used in conscious cynomolgus monkeys for regulatory safety pharmacology. Part 2: Pharmacological validation

Simon Authier et al. J Pharmacol Toxicol Methods. 2007 Sep-Oct.

Abstract

Introduction: This project addresses the validation study design of a test system using a telemetered non-human primate model for cardiovascular safety pharmacology evaluation.

Methods: In addition to non-pharmacological validation including installation and operation qualifications, performance qualification (locomotor activity and cardiovascular evaluations) was completed on free-moving cynomolgus monkeys by quantifying the degree of cardiovascular response measured by the telemetric device to various positive control drugs following their intravenous administration. Remifentanil (0.0005, 0.001, 0.002, 0.004, 0.008 and 0.016 mg/kg) was given to induce bradycardia and hypotension. Medetomidine (0.04 mg/kg) was used to induce an initial phase of hypertension followed by hypotension and bradycardia. Esmolol (0.5, 1.0 and 2.0 mg/kg) was used to induce bradycardia. Dopamine (0.002, 0.008, 0.01, 0.02, 0.03 and 0.05 mg/kg/min) was infused over 30 min to induce an increase in arterial and pulse pressures and tachycardia. Amiodarone (0.4, 0.8 and 1.6 mg/kg/min) was infused over 10 min to induce QT interval prolongation. Potassium chloride (0.08 mEq/kg/min) was infused for periods of less than 30 min to induce electrocardiographic (EKG) changes characteristic of hyperkalemia. Reliability was evaluated over 60 days.

Results: Monitoring with a reference methodology and the telemetry system was important in order to evaluate precision and accuracy of the test system. Positive control drugs produced a wide range of cardiovascular effects with different amplitudes, which were useful in identification of the limits of the test system.

Discussion: Reference monitoring methods and selection of a battery of positive control drugs are important to ensure proper test system validation. Drugs inducing not only QT prolongation but also positive and negative chronotropic effects, positive and negative systemic arterial pressure changes and ECG morphology alterations were useful to identify test system limitations during performance qualification. ECG data processing at significantly elevated heart rates revealed that a trained observer should review all cardiac cycles evaluated by computer.