Review
. 2008 Mar;18(2):211-30.
doi: 10.1038/sj.jes.7500591. Epub 2007 Jun 27.

Comparative evaluation of absorbed dose estimates derived from passive dosimetry measurements to those derived from biological monitoring: validation of exposure monitoring methodologies

Affiliations
Review

Comparative evaluation of absorbed dose estimates derived from passive dosimetry measurements to those derived from biological monitoring: validation of exposure monitoring methodologies

John Ross et al. J Expo Sci Environ Epidemiol. 2008 Mar.

Abstract

Passive dosimetry (PD) methods for measuring and estimating exposure to agricultural workers (i.e., persons handling agricultural chemicals and working in treated crops) have been in use since the 1950s. A large number of studies were conducted in the 1950s through 1970s to characterize exposure. Since the 1980s quantitative dermal PD methods are used in conjunction with inhalation PD methods to measure whole-body exposure. These exposure or absorbed dose estimates are then compared to "no effect" exposure levels for hazards identified in toxicology studies, and have become the standard for risk assessment for regulatory agencies. The PD methods used have never been validated. Validation in the context of human exposure monitoring methods means that a method has been shown to measure accurately a delivered dose in humans. The most practical alternative to isolating parts of the body for validating recovery methods is to utilize field exposure studies in which concurrent or consecutive measurements of exposure and absorbed dose have been made with PD and biomonitoring in the same cohorts of individuals. This ensures that a direct comparison can be made between the two estimates of absorbed dose, one derived from PD and the other from biomonitoring. There are several studies available (published and proprietary) employing both of these approaches. Reports involving 14 concurrent or consecutive PD-biomonitoring studies were quantitatively evaluated with 18 different methods of application or reentry scenarios for eight different active ingredients for which measured human kinetics and dermal absorption data existed. This evaluation demonstrated that the total absorbed dose estimated using PD for important handler and reentry scenarios is generally similar to the measurements for those same scenarios made using human urinary biomonitoring methods. The statistical analysis of individual worker PD:biomonitoring ratios showed them to be significantly correlated in these studies. The PD techniques currently employed yield a reproducible, standard methodology that is valid and reliably quantifies exposure.