Evaluation and measurement of magnetic field exposure at a typical high-voltage substation and its power lines
- PMID: 17595208
- DOI: 10.1093/rpd/ncm326
Evaluation and measurement of magnetic field exposure at a typical high-voltage substation and its power lines
Abstract
This study presents a survey of magnetic field measurements including those resulting from 380/154 kV power substations, which play a vital role in human body biological studies. The survey was carried out in the main power substation of Antalya, Turkey, located at the suburban region of the city, under actual loads. The paper also presents the actual magnetic field strength measured near the 380/154 kV substation and power transmission lines (380 and 154 kV) connecting to the substation. Since most part of these lines pass through a residential area, they have been included in the study, and the actual magnetic field variation around them has been investigated by comparative analysis of measured data. For the occupants working at substations, occupational exposure has been analysed with actual magnetic fields at operating locations. Induced internal electric fields and current densities in the occupants' body due to exposure to external magnetic fields produced by a conventional 380/154 kV power substation have been investigated.
Similar articles
-
Assessment of occupational exposure to magnetic fields in high-voltage substations (154/34.5 kV).Radiat Prot Dosimetry. 2008;128(4):464-70. doi: 10.1093/rpd/ncm443. Epub 2007 Oct 23. Radiat Prot Dosimetry. 2008. PMID: 17959609
-
Public magnetic field exposure based on internal current density for electric low voltage systems.Health Phys. 2009 Apr;96(4):423-31. doi: 10.1097/01.HP.0000336982.69600.bf. Health Phys. 2009. PMID: 19276702
-
Measurements of ELF electromagnetic exposure of the general public from Belgian power distribution substations.Health Phys. 2008 Jan;94(1):57-66. doi: 10.1097/01.HP.0000282043.53270.fd. Health Phys. 2008. PMID: 18091152
-
[Evaluation of reports on environmental measurements of electromagnetic fields generated by high voltage transmission lines and substations].Med Pr. 2007;58(2):169-75. Med Pr. 2007. PMID: 17926507 Review. Polish.
-
Variability and consistency of electric and magnetic field occupational exposure measurements.J Expo Anal Environ Epidemiol. 1996 Jul-Sep;6(3):355-74. J Expo Anal Environ Epidemiol. 1996. PMID: 8889954 Review.
Cited by
-
Occupational exposure to electric and magnetic fields during tasks at ground or floor level at 110 kV substations in Finland.Int J Occup Saf Ergon. 2016 Sep;22(3):384-8. doi: 10.1080/10803548.2016.1153858. Epub 2016 Apr 14. Int J Occup Saf Ergon. 2016. PMID: 27075421 Free PMC article.
-
Evaluation of the electromagnetic field intensity in operating rooms and estimation of occupational exposures of personnel.Interv Med Appl Sci. 2018 Sep;10(3):121-126. doi: 10.1556/1646.10.2018.18. Interv Med Appl Sci. 2018. PMID: 30713749 Free PMC article.
-
Extremely low-frequency electromagnetic fields disrupt magnetic alignment of ruminants.Proc Natl Acad Sci U S A. 2009 Apr 7;106(14):5708-13. doi: 10.1073/pnas.0811194106. Epub 2009 Mar 19. Proc Natl Acad Sci U S A. 2009. PMID: 19299504 Free PMC article.
-
50 Hz Temporal Magnetic Field Monitoring from High-Voltage Power Lines: Sensor Design and Experimental Validation.Sensors (Basel). 2024 Aug 17;24(16):5325. doi: 10.3390/s24165325. Sensors (Basel). 2024. PMID: 39205019 Free PMC article.
-
The monitoring results of electromagnetic radiation of 110-kV high-voltage lines in one urban location in Chongqing P.R. China.Environ Monit Assess. 2012 Mar;184(3):1533-40. doi: 10.1007/s10661-011-2058-y. Epub 2011 Jun 29. Environ Monit Assess. 2012. PMID: 21713502
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical