Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2007 Oct;22(10):2978-84.
doi: 10.1093/ndt/gfm137. Epub 2007 Jun 27.

The AN69 ST haemodialysis membrane under conditions of two different extracorporeal circuit rinse protocols a comparison of thrombogenicity parameters

Affiliations
Randomized Controlled Trial

The AN69 ST haemodialysis membrane under conditions of two different extracorporeal circuit rinse protocols a comparison of thrombogenicity parameters

Pavlina Richtrova et al. Nephrol Dial Transplant. 2007 Oct.

Abstract

Background: Thrombogenicity is an important parameter of haemodialysis (HD) membrane biocompatibility. The surface of the polyacrylonitrile AN69 ST membrane is coated with a polyethylenimine. This modification allows heparin adsorption. The binding of heparin to the membrane surface occurs during priming of the extracorporeal circuit (ECC) by rinsing it with saline and heparin. Our aims were to assess and compare the thrombogenicity of the AN69 ST membrane under conditions of two extracorporeal circuit (ECC) rinse protocols-with and without unfractionated heparin (UFH).

Methods: In a prospective, crossover and randomized study, we examined 10 patients during HD after ECC preparation with either rinse protocols. Prior to HD and at 15, 60 and 240 min, we determined plasma levels of the thrombin-antithrombin complexes (TAT), platelet factor 4 (PF4), heparin concentration (antiXa) and thrombocyte count. Systemic anticoagulation was performed using UFH.

Results: During HD after ECC rinse without UFH, there was a significantly earlier and more marked increase in TAT compared with UFH-containing rinse (P <0.05). Using Spearman coefficient, we demonstrated a significant correlation between TAT and antiXa at 60 min (r = -0.534) and 240 min (r = -0.538). A comparison of the TAT/antiXa ratios between rinses at 60 min revealed a significantly higher increase in TAT following UFH-free rinse (P <0.05). There was no difference in PF4 between the rinses. Platelet count did not change significantly during HD using either rinse protocol.

Conclusion: Based on plasma TAT levels, ECC priming with an UFH-containing solution reduces the thrombogenicity of the AN69 ST membrane. There is no significant difference between both types of priming concerning PF4 and thrombocyte count.