Creation of a uniform pleural defect model for the study of lung sealants
- PMID: 17599500
- DOI: 10.1016/j.jtcvs.2007.01.007
Creation of a uniform pleural defect model for the study of lung sealants
Abstract
Objective: Animal models are indispensable for the development of new therapeutic methods for the closure of alveolar air leakage. However, it is difficult to create a uniform pleural defect model. The purpose of this study was to establish an appropriate animal model for assessing the efficacy and histotoxicity of synthetic sealants for lung surgery.
Methods: Nine beagle dogs were used to evaluate the pleural defect model in comparison with conventional resection procedures. A donut-shaped silicon ring with an inner diameter of 15 mm was placed on the pleura, and 0.1 mL of cyanoacrylate was dropped into the ring. A pleural defect was created by sliding a microtome blade just beneath the polymerized cyanoacrylate. Hemostasis was performed by pressure with a sponge.
Results: Morphologically, round areas of the pleura were uniformly resected with our procedure. The resected tissue consisted of pleura and thin underlying lung parenchyma. Among the results from 3 surgeons, there were no significant differences in the mean time required for hemostasis (P = .69), the mean thickness of the resected tissue (P = .13), and the mean amount of air leakage from the resected area (P = .19). No penetration of cyanoacrylate into the lung parenchyma was evidenced by immunofluorescence microscopy. Histologically, when the pleura was resected without using cyanoacrylate, a thick fibrocellular layer extended to the lung parenchyma. Furthermore, severe fibrosis was observed when electrocautery was used for hemostasis. However, when the pleura was resected using cyanoacrylate, the normal alveolar structure was preserved.
Conclusions: Our uniform pleural defect model using cyanoacrylate may be feasible for the evaluation of synthetic sealants for alveolar air leakage.
Similar articles
-
A novel technique to prevent intra-operative pneumothorax in awake coronary artery bypass grafting: biomaterial neo-pleura.Eur J Cardiothorac Surg. 2009 Jan;35(1):37-41. doi: 10.1016/j.ejcts.2008.07.067. Epub 2008 Sep 27. Eur J Cardiothorac Surg. 2009. PMID: 18824372
-
Triple-layer sealing with absorptive mesh and fibrin glue is effective in preventing air leakage after segmentectomy: results from experiments and clinical study.Eur J Cardiothorac Surg. 2014 May;45(5):910-3. doi: 10.1093/ejcts/ezt502. Epub 2013 Oct 24. Eur J Cardiothorac Surg. 2014. PMID: 24157483
-
Efficacy of a sheet combined with fibrin glue in repair of pleural defect at the early phase after lung surgery in a canine model.Gen Thorac Cardiovasc Surg. 2018 Feb;66(2):103-107. doi: 10.1007/s11748-017-0857-y. Epub 2017 Nov 3. Gen Thorac Cardiovasc Surg. 2018. PMID: 29101533
-
The current status of cyanoacrylate and fibrin tissue adhesives.J Long Term Eff Med Implants. 1992;2(4):221-33. J Long Term Eff Med Implants. 1992. PMID: 10148000 Review.
-
Pleural fibrosis.Clin Chest Med. 2006 Jun;27(2):181-91. doi: 10.1016/j.ccm.2005.12.003. Clin Chest Med. 2006. PMID: 16716812 Review.
Cited by
-
Elastic sealants for surgical applications.Eur J Pharm Biopharm. 2015 Sep;95(Pt A):27-39. doi: 10.1016/j.ejpb.2015.05.022. Epub 2015 Jun 12. Eur J Pharm Biopharm. 2015. PMID: 26079524 Free PMC article. Review.
-
Ocular adhesives: Design, chemistry, crosslinking mechanisms, and applications.Biomaterials. 2019 Mar;197:345-367. doi: 10.1016/j.biomaterials.2019.01.011. Epub 2019 Jan 7. Biomaterials. 2019. PMID: 30690421 Free PMC article. Review.
-
Aldehyde-amine chemistry enables modulated biosealants with tissue-specific adhesion.Adv Mater. 2009 Sep 4;21(32-33):3399-403. doi: 10.1002/adma.200900340. Adv Mater. 2009. PMID: 20882504 Free PMC article. No abstract available.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources