A method for noncontact measurement of corneal diameter in children
- PMID: 17601441
- DOI: 10.1016/j.ajo.2007.03.021
A method for noncontact measurement of corneal diameter in children
Abstract
Purpose: To evaluate a new method for measuring corneal diameter in children.
Design: Prospective, cross-sectional study.
Methods: With a digital camera set at maximum focal distance, the authors photographed 92 children twice, each with a paper ruler taped to his or her forehead. Images were opened on a personal computer and the lower half of each eye was cut out and dragged to the ruler to record corneal diameter. The coefficient of variation was calculated for each eye, and nonlinear regression analysis used to correlate diameters with age.
Results: Directly after birth, corneal diameter was 9.98 mm, increasing to a plateau of 11.51 mm within the first 24 months of life. The coefficient of variation was 1.3%. Each measurement took no more than a few minutes.
Conclusions: This method allows very precise, fast, noncontact measurements of corneal diameter in newborn and young children.
Similar articles
-
Growth of the cornea from infancy to adolescence.Ophthalmic Physiol Opt. 2006 Jan;26(1):80-7. doi: 10.1111/j.1475-1313.2005.00362.x. Ophthalmic Physiol Opt. 2006. PMID: 16390486
-
[Central corneal thickness measurements in children].Klin Oczna. 2005;107(7-9):442-4. Klin Oczna. 2005. PMID: 16416992 Polish.
-
Does endothelial cell density correlate with corneal diameter in a group of young adults?Cornea. 2008 Jul;27(6):640-3. doi: 10.1097/QAI.0b013e31815e4062. Cornea. 2008. PMID: 18580253
-
Rapid measurement of corneal diameter in children: validation of a clinic-based digital photographic technique.J AAPOS. 2009 Jun;13(3):287-8. doi: 10.1016/j.jaapos.2009.01.006. J AAPOS. 2009. PMID: 19541269 Clinical Trial.
-
Estimation of pupil size by digital photography.J Cataract Refract Surg. 2004 Feb;30(2):381-9. doi: 10.1016/S0886-3350(03)00619-9. J Cataract Refract Surg. 2004. PMID: 15030828
Cited by
-
Deep-learning approach to detect childhood glaucoma based on periocular photograph.Sci Rep. 2023 Jun 22;13(1):10141. doi: 10.1038/s41598-023-37389-2. Sci Rep. 2023. PMID: 37349526 Free PMC article.
-
Patients within the Broad Holoprosencephaly Spectrum have Distinct and Subtle Ophthalmologic Anomalies: Response to Khan.Am J Med Genet A. 2012 May;158A(5):1244-1245. doi: 10.1002/ajmg.a.35207. Epub 2012 Feb 7. Am J Med Genet A. 2012. PMID: 22645505 Free PMC article. No abstract available.
-
Validating the use of U-tool as a novel method for measuring the corneal diameter in infants screened for congenital glaucoma.Indian J Ophthalmol. 2022 Jan;70(1):143-146. doi: 10.4103/ijo.IJO_930_21. Indian J Ophthalmol. 2022. PMID: 34937226 Free PMC article.
-
White-to-white corneal diameter distribution in an adult population.J Curr Ophthalmol. 2015 Oct 19;27(1-2):21-4. doi: 10.1016/j.joco.2015.09.001. eCollection 2015 Mar-Jun. J Curr Ophthalmol. 2015. PMID: 27239570 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources