CT dose optimization when changing to CT multi-detector row technology
- PMID: 17601537
- DOI: 10.1067/j.cpradiol.2007.04.001
CT dose optimization when changing to CT multi-detector row technology
Abstract
The purpose of this article was to review the strategies to control patient dose in adult and pediatric computed tomography (CT), taking into account the change of technology from single-detector row CT to multi-detector row CT. First the relationships between computed tomography dose index, dose length product, and effective dose in adult and pediatric CT are revised, along with the diagnostic reference level concept. Then the effect of image noise as a function of volume computed tomography dose index, reconstructed slice thickness, and the size of the patient are described. Finally, the potential of tube current modulation CT is discussed.
Similar articles
-
[Single-slice and multi-slice computerized tomography: dosimetric comparison with diagnostic reference dose levels].Radiol Med. 2001 Oct;102(4):262-5. Radiol Med. 2001. PMID: 11740455 Italian.
-
Computed tomography radiation dose optimization: scanning protocols and clinical applications of automatic exposure control.Curr Probl Diagn Radiol. 2005 Sep-Oct;34(5):171-81. doi: 10.1067/j.cpradiol.2005.06.002. Curr Probl Diagn Radiol. 2005. PMID: 16129235 Review.
-
Dose performance of a 64-channel dual-source CT scanner.Radiology. 2007 Jun;243(3):775-84. doi: 10.1148/radiol.2433061165. Epub 2007 Apr 19. Radiology. 2007. PMID: 17446525
-
The relevance of image quality indices for dose optimization in abdominal multi-detector row CT in children: experimental assessment with pediatric phantoms.Phys Med Biol. 2009 Apr 7;54(7):1871-92. doi: 10.1088/0031-9155/54/7/002. Epub 2009 Mar 5. Phys Med Biol. 2009. PMID: 19265204
-
Recent technologic advances in multi-detector row cardiac CT.Cardiol Clin. 2009 Nov;27(4):655-64. doi: 10.1016/j.ccl.2009.06.007. Cardiol Clin. 2009. PMID: 19766922 Review.
Cited by
-
Solitary pulmonary nodule on helical dynamic CT scans: analysis of the enhancement patterns using a computer-aided diagnosis (CAD) system.Korean J Radiol. 2008 Sep-Oct;9(5):401-8. doi: 10.3348/kjr.2008.9.5.401. Korean J Radiol. 2008. PMID: 18838848 Free PMC article.
-
Implementing tin-prefiltration in routine clinical CT scans of the lower extremity: impact on radiation dose.Skeletal Radiol. 2025 Sep;54(9):1915-1925. doi: 10.1007/s00256-025-04897-3. Epub 2025 Feb 26. Skeletal Radiol. 2025. PMID: 40011260 Free PMC article.
-
Fast kilovoltage-switching dual-energy CT offering lower x-ray dose than single-energy CT for the chest: a quantitative and qualitative comparison study of the two methods of acquisition.Diagn Interv Radiol. 2019 May;25(3):204-209. doi: 10.5152/dir.2019.18412. Diagn Interv Radiol. 2019. PMID: 31085505 Free PMC article.
-
CT dose management for neurologic events in patients with cardiac devices: Radiation exposure variation in patients with cardiac devices.Diagn Interv Radiol. 2022 Jan;28(1):98-102. doi: 10.5152/dir.2021.20673. Diagn Interv Radiol. 2022. PMID: 34914608 Free PMC article.
-
Low-dose unenhanced CT protocols according to individual body size for evaluating suspected renal colic: cumulative radiation exposures.Radiol Med. 2010 Feb;115(1):105-14. doi: 10.1007/s11547-009-0476-5. Epub 2009 Dec 16. Radiol Med. 2010. PMID: 20017007 English, Italian.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical