Reliability of centre of pressure summary measures of postural steadiness in healthy young adults
- PMID: 17601736
- DOI: 10.1016/j.gaitpost.2007.05.008
Reliability of centre of pressure summary measures of postural steadiness in healthy young adults
Abstract
This study aimed to (1) estimate the reliability of 36 centre of pressure (COP) summary measures in healthy participants and (2) identify the main sources of variability in order to estimate the most appropriate measurement strategies to improve reliability. Twelve healthy males performed, on two separate days, eight 1-min trials of quiet standing on a force platform in two conditions [eyes open (EO) and eyes closed (EC)]. The generalizability theory was used as a framework to estimate the magnitude of the different variance components (Subject, Trial, Day and all interactions) and the reliability of the measures corresponding to various simulations of measurement strategies. Reliability of the COP summary measures was poor to moderate. Intra-class correlation coefficients were generally higher with EO (mean: 0.46, range: 0.03-0.76) than with EC (mean: 0.41, range 0.02-0.72) across all summary measures. The majority of the variance was attributed to Subject (2%-76%), Subject x Day (0%-24%) and Subject x Day x Trial (16%-79%) variance components depending on the summary measure and condition. The reliability could be improved more efficiently by averaging measurements between-days than by increasing the number of trials during 1 day. For the majority of the summary measures, acceptable reliability can be achieved when at least seven or more trials are averaged during the same testing day.
Similar articles
-
Intrasession reliability of force platform parameters in community-dwelling older adults.Arch Phys Med Rehabil. 2008 Oct;89(10):1977-82. doi: 10.1016/j.apmr.2008.02.033. Arch Phys Med Rehabil. 2008. PMID: 18929026
-
Generalizability of Stabilogram Diffusion Analysis of center of pressure measures.Gait Posture. 2008 Feb;27(2):223-30. doi: 10.1016/j.gaitpost.2007.03.013. Epub 2007 May 4. Gait Posture. 2008. PMID: 17482466
-
Reliability of traditional and fractal dimension measures of quiet stance center of pressure in young, healthy people.Arch Phys Med Rehabil. 2005 Oct;86(10):2034-40. doi: 10.1016/j.apmr.2005.05.014. Arch Phys Med Rehabil. 2005. PMID: 16213250 Clinical Trial.
-
Generalizability of center of pressure measures of quiet standing.Gait Posture. 2007 Feb;25(2):166-71. doi: 10.1016/j.gaitpost.2006.03.004. Epub 2006 Apr 19. Gait Posture. 2007. PMID: 16624560
-
Measuring the balance control system--review.Acta Medica (Hradec Kralove). 2008;51(3):129-37. Acta Medica (Hradec Kralove). 2008. PMID: 19271679 Review.
Cited by
-
Universal and individual characteristics of postural sway during quiet standing in healthy young adults.Physiol Rep. 2015 Mar;3(3):e12329. doi: 10.14814/phy2.12329. Physiol Rep. 2015. PMID: 25780094 Free PMC article.
-
Training intensity quantification of core stability exercises based on a smartphone accelerometer.PLoS One. 2018 Dec 5;13(12):e0208262. doi: 10.1371/journal.pone.0208262. eCollection 2018. PLoS One. 2018. PMID: 30517171 Free PMC article. Clinical Trial.
-
Agreement of Three Posturographic Force Plates in the Assessment of Postural Stability.Int J Environ Res Public Health. 2020 May 4;17(9):3188. doi: 10.3390/ijerph17093188. Int J Environ Res Public Health. 2020. PMID: 32375315 Free PMC article.
-
An Active Learning Algorithm for Control of Epidural Electrostimulation.IEEE Trans Biomed Eng. 2015 Oct;62(10):2443-2455. doi: 10.1109/TBME.2015.2431911. Epub 2015 May 12. IEEE Trans Biomed Eng. 2015. PMID: 25974925 Free PMC article.
-
Relation between postural control assessment with eyes open and centre of pressure visual feedback effects in healthy individuals.Exp Brain Res. 2009 May;195(1):145-52. doi: 10.1007/s00221-009-1761-1. Epub 2009 Mar 24. Exp Brain Res. 2009. PMID: 19308364
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical