Rapid and simple liquid chromatography tandem mass spectrometry method for the quantification of zidovudine in rat plasma
- PMID: 17604365
- DOI: 10.1002/bmc.888
Rapid and simple liquid chromatography tandem mass spectrometry method for the quantification of zidovudine in rat plasma
Abstract
A high-performance liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the quantification of zidovudine in rat plasma. Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reverse phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 268/127 for zidovudine and m/z 230/112 for the internal standard. The method exhibited a linear dynamic range of 5-500 ng/mL for zidovudine in rat plasma. The lower limit of quantification was 5 ng/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 1.5 min for each sample made it possible to analyze more than 400 plasma samples per day. The validated method was applied for pharmacokinetic studies of the novel drug delivery systems of zidovudine in rats.
Copyright (c) 2007 John Wiley & Sons, Ltd.
Similar articles
-
Quantification of pseudoephedrine in human plasma by LC-MS/MS using mosapride as internal standard.Biomed Chromatogr. 2007 Mar;21(3):241-8. doi: 10.1002/bmc.745. Biomed Chromatogr. 2007. PMID: 17230461
-
Quantification of fexofenadine in human plasma by liquid chromatography coupled to electrospray tandem mass spectrometry using mosapride as internal standard.Biomed Chromatogr. 2007 Feb;21(2):209-16. doi: 10.1002/bmc.740. Biomed Chromatogr. 2007. PMID: 17221908
-
Sensitive liquid chromatography tandem mass spectrometry method for the quantification of Quetiapine in plasma.Biomed Chromatogr. 2008 Oct;22(10):1043-55. doi: 10.1002/bmc.1012. Biomed Chromatogr. 2008. PMID: 18781706
-
Identification of dauricine and its metabolites in rat urine by liquid chromatography-tandem mass spectrometry.J Chromatogr B Analyt Technol Biomed Life Sci. 2007 Jul 1;854(1-2):1-7. doi: 10.1016/j.jchromb.2007.03.036. Epub 2007 Apr 5. J Chromatogr B Analyt Technol Biomed Life Sci. 2007. PMID: 17448738 Review.
-
Quantification of polar drugs in human plasma with liquid chromatography-tandem mass spectrometry.Bioanalysis. 2009 Apr;1(1):187-203. doi: 10.4155/bio.09.19. Bioanalysis. 2009. PMID: 21083196 Review.
Cited by
-
Validation of a sensitive LC/MS/MS method for the determination of zidovudine and lamivudine in human plasma.Biomed Chromatogr. 2012 Jan;26(1):12-20. doi: 10.1002/bmc.1617. Epub 2011 Apr 4. Biomed Chromatogr. 2012. PMID: 21465499 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources