. 1991 Nov;60(5):1229-42.
doi: 10.1016/S0006-3495(91)82157-9.

Flow rate measurements in isolated perfused kidney tubules by fluorescence photobleaching recovery

Affiliations

Flow rate measurements in isolated perfused kidney tubules by fluorescence photobleaching recovery

B Flamion et al. Biophys J. 1991 Nov.

Abstract

We have developed a new application of the fluorescence photobleaching recovery (FPR) technique for instantaneous measurement of volume flow rates at any axial position along isolated perfused kidney tubules. The method requires fast data acquisition of emitted fluorescence through a photomultiplier (time resolution, 0.5 ms) coupled with differential interference contrast microscopy to measure luminal diameters accurately. While the tubule is perfused in vitro with an impermeant fluorophore (fluorescein sulfonate), a 20-ms bleach pulse reduces the fluorescence in the observation region by 20-25%. Fluorescence recovery is a direct function of perfusate velocity; diffusion plays no significant role in the early phase of recovery. A fluid dynamics approach to data analysis shows that fractional recovery increases linearly with time until t = L/2vm, where L is the length of the observation window and vm is the mean axial velocity. Practically, a linear regression analysis of the early recovery phase allows measurement of vm of up to 0.14 cm/s, i.e., a 40-nl/min flow rate in a 25-microns-diameter tubule. Calibration experiments in small glass tubes perfused at predetermined flow rates demonstrated good accuracy (within 10%) and reproducibility (coefficient of variation, 8.7%). In rat inner medullary collecting ducts microperfused at 4-40 nl/min, the correlation with a standard fluid collection method was excellent (r2 greater than 0.97). The method should also be suitable for the direct measurement of fluid flow rate in kidney tubules or blood vessels microperfused in vivo.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Biomech. 1969 Mar;2(1):105-19 - PubMed
    1. Am J Physiol. 1966 Jun;210(6):1293-8 - PubMed
    1. Biophys J. 1990 Oct;58(4):873-85 - PubMed
    1. J Cell Biol. 1985 Apr;100(4):1309-23 - PubMed
    1. Am J Physiol. 1989 Nov;257(5 Pt 1):C837-50 - PubMed

LinkOut - more resources