Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2007 Jul;9(7):718-29.
doi: 10.1039/b702844j. Epub 2007 May 18.

Solid-phase extraction followed by liquid chromatography-time-of-flight-mass spectrometry to evaluate pharmaceuticals in effluents. A pilot monitoring study

Affiliations

Solid-phase extraction followed by liquid chromatography-time-of-flight-mass spectrometry to evaluate pharmaceuticals in effluents. A pilot monitoring study

María José Gómez et al. J Environ Monit. 2007 Jul.

Abstract

The present work provides a multi-residue analytical method for determining a selection of 20 pharmaceuticals from diverse therapeutical classes in hospital effluent wastewater. The method is based on the simultaneous extraction of the target compounds by solid phase extraction (SPE), followed by liquid chromatography-time-of-flight-mass spectrometry (LC-TOF-MS) analysis. Using TOF-MS, accurate mass measurements within 2 ppm error were obtained for most of the pharmaceuticals studied. Empirical formula information can be obtained by this method, allowing the unequivocal identification of the target compounds in the samples. Validation studies showed that LC-TOF-MS analysis is a valuable new tool for identification and quantification of pharmaceuticals in wastewater. Recoveries, using Oasis HLB cartridges at pH 7, were higher than 75% for all pharmaceuticals, except for ranitidine, 4-methylaminoantipyrine (4-MAA), cefotaxime and omeprazole, which needed specific pH conditions for their extraction. Linearity of response over two orders of magnitude was demonstrated (r > 0.99). Matrix effects resulting in suppression of the response were observed. For most of the compounds ion suppression was less than 39%, except for metronidazole, carbamazepine 10,11-epoxide, naproxen and erythromycin, where the signal suppression was 42%, 59%, 46% and 95%, respectively. A simple and effective approach to minimize or avoid matrix interferences was the 1 : 4 dilution of the SPE extracts. Method detection limits (MDLs) and quantification limits (MQLs) ranged between 4-115 ng l(-1) and 14-384 ng l(-1), respectively. The precision of the method, calculated as relative standard deviation (RSD), ranged from 1.1-19.8% and 1.7-21.7% for intra- and inter-day, respectively. The developed analytical method was applied to the analysis of hospital effluent wastewater during a survey study. 18 of the 20 pharmaceuticals studied were detected at concentration levels of microg l(-1), reaching in some cases concentrations over 100 microg l(-1), and in the case of the analgesic and antipyretic dipyrone metabolite, higher than 1000 microg l(-1).

PubMed Disclaimer

Similar articles

Cited by

Publication types

Substances

LinkOut - more resources