Solid-phase extraction followed by liquid chromatography-time-of-flight-mass spectrometry to evaluate pharmaceuticals in effluents. A pilot monitoring study
- PMID: 17607393
- DOI: 10.1039/b702844j
Solid-phase extraction followed by liquid chromatography-time-of-flight-mass spectrometry to evaluate pharmaceuticals in effluents. A pilot monitoring study
Abstract
The present work provides a multi-residue analytical method for determining a selection of 20 pharmaceuticals from diverse therapeutical classes in hospital effluent wastewater. The method is based on the simultaneous extraction of the target compounds by solid phase extraction (SPE), followed by liquid chromatography-time-of-flight-mass spectrometry (LC-TOF-MS) analysis. Using TOF-MS, accurate mass measurements within 2 ppm error were obtained for most of the pharmaceuticals studied. Empirical formula information can be obtained by this method, allowing the unequivocal identification of the target compounds in the samples. Validation studies showed that LC-TOF-MS analysis is a valuable new tool for identification and quantification of pharmaceuticals in wastewater. Recoveries, using Oasis HLB cartridges at pH 7, were higher than 75% for all pharmaceuticals, except for ranitidine, 4-methylaminoantipyrine (4-MAA), cefotaxime and omeprazole, which needed specific pH conditions for their extraction. Linearity of response over two orders of magnitude was demonstrated (r > 0.99). Matrix effects resulting in suppression of the response were observed. For most of the compounds ion suppression was less than 39%, except for metronidazole, carbamazepine 10,11-epoxide, naproxen and erythromycin, where the signal suppression was 42%, 59%, 46% and 95%, respectively. A simple and effective approach to minimize or avoid matrix interferences was the 1 : 4 dilution of the SPE extracts. Method detection limits (MDLs) and quantification limits (MQLs) ranged between 4-115 ng l(-1) and 14-384 ng l(-1), respectively. The precision of the method, calculated as relative standard deviation (RSD), ranged from 1.1-19.8% and 1.7-21.7% for intra- and inter-day, respectively. The developed analytical method was applied to the analysis of hospital effluent wastewater during a survey study. 18 of the 20 pharmaceuticals studied were detected at concentration levels of microg l(-1), reaching in some cases concentrations over 100 microg l(-1), and in the case of the analgesic and antipyretic dipyrone metabolite, higher than 1000 microg l(-1).
Similar articles
-
Determination of pharmaceuticals of various therapeutic classes by solid-phase extraction and liquid chromatography-tandem mass spectrometry analysis in hospital effluent wastewaters.J Chromatogr A. 2006 May 12;1114(2):224-33. doi: 10.1016/j.chroma.2006.02.038. Epub 2006 Mar 20. J Chromatogr A. 2006. PMID: 16546199
-
Application of liquid chromatography/quadrupole-linear Ion trap mass spectrometry and time-of-flight mass spectrometry to the determination of pharmaceuticals and related contaminants in wastewater.Anal Chem. 2007 Dec 15;79(24):9372-84. doi: 10.1021/ac0715672. Epub 2007 Nov 15. Anal Chem. 2007. PMID: 18001124
-
Multi-residue analytical method for the determination of emerging pollutants in water by solid-phase extraction and liquid chromatography-tandem mass spectrometry.J Chromatogr A. 2009 Apr 3;1216(14):2958-69. doi: 10.1016/j.chroma.2008.09.041. Epub 2008 Sep 17. J Chromatogr A. 2009. PMID: 18834589
-
Advantages and limitations of on-line solid phase extraction coupled to liquid chromatography-mass spectrometry technologies versus biosensors for monitoring of emerging contaminants in water.J Chromatogr A. 2007 Jun 8;1152(1-2):97-115. doi: 10.1016/j.chroma.2007.01.046. Epub 2007 Jan 18. J Chromatogr A. 2007. PMID: 17275010 Review.
-
Novel analytical procedures for screening of drug residues in water, waste water, sediment and sludge.Anal Chim Acta. 2007 Jun 19;593(2):129-39. doi: 10.1016/j.aca.2007.05.006. Epub 2007 May 6. Anal Chim Acta. 2007. PMID: 17543599 Review.
Cited by
-
Oxidative removal of metronidazole from aqueous solution by thermally activated persulfate process: kinetics and mechanisms.Environ Sci Pollut Res Int. 2018 Jan;25(3):2466-2475. doi: 10.1007/s11356-017-0518-9. Epub 2017 Nov 10. Environ Sci Pollut Res Int. 2018. PMID: 29127632
-
Novel Insights into Selection for Antibiotic Resistance in Complex Microbial Communities.mBio. 2018 Jul 24;9(4):e00969-18. doi: 10.1128/mBio.00969-18. mBio. 2018. PMID: 30042197 Free PMC article.
-
Validated Simultaneous Gradient Ultra-Performance Liquid Chromatographic Quantification of Some Proton Pump Inhibitor Drug Residues in Saudi Pharmaceutical Industrial Wastewater.Molecules. 2021 Jul 19;26(14):4358. doi: 10.3390/molecules26144358. Molecules. 2021. PMID: 34299632 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical