Bone level changes at axial- and non-axial-positioned implants supporting fixed partial dentures. A 5-year retrospective longitudinal study
- PMID: 17608740
- DOI: 10.1111/j.1600-0501.2007.01386.x
Bone level changes at axial- and non-axial-positioned implants supporting fixed partial dentures. A 5-year retrospective longitudinal study
Abstract
Aim: The aim of this study was to retrospectively analyze the potential influence of implant inclination on marginal bone loss at freestanding, implant-supported, fixed partial dentures (FPDs) over a 5-year period of functional loading.
Material and methods: The material comprised 38 periodontally treated, partially dentate patients with a total of 42 free-standing FPDs supported by implants of the Astra Tech System. Mesio-distal inclination of the implants in relation to a vertical axis perpendicular to the occlusal plane was measured with a protractor on standardized photographs of the master cast. The two tail quartiles of the distribution of the implants with regard to the implant inclination were defined as axial-positioned (mean 2.4 degrees; range 0-4 degrees) and non-axial-positioned implants (mean 17.1 degrees; range 11-30 degrees), respectively. For FPDs supported by two implants, both the mesial-distal and buccal-lingual inter-implant inclination was measured. The primary outcome variable was change in peri-implant bone level from the time of FPD placement to the 5-year follow-up examination. Comparison between axial- and non-axial-positioned implants was performed by the use of a Mann-Whitney U-test. Spearman's correlation analysis was used to analyze relationships between inter-implant inclination (mesial-distal and buccal-lingual) and 5-year bone level change on the FPD level.
Results: The 5-year mean bone level change amounted to 0.4 mm (SD 0.97) for the axial and 0.5 mm (0.95) for non-axial-positioned implants (P>0.05). For the FPDs supported by two implants, the mean inter-implant inclination was 9.2 degrees (1-36 degrees) in the mesial-distal direction and 6.7 degrees (0-24 degrees) in the buccal-lingual direction. Correlation analysis revealed lack of statistically significant correlation between inter-implant inclination (mesial-distal and buccal-lingual) and 5-year bone level change (r=-0.19 and r=-0.32, respectively).
Conclusion: The study failed to support the hypothesis that implant inclination has an effect on peri-implant bone loss.
Similar articles
-
Submerged or non-submerged healing of endosseous implants to be used in the rehabilitation of partially dentate patients.J Clin Periodontol. 2004 Apr;31(4):299-308. doi: 10.1111/j.1600-051X.2004.00527.x. J Clin Periodontol. 2004. PMID: 15016259 Clinical Trial.
-
Two-year prospective follow-up of implant/tooth-supported versus freestanding implant-supported fixed partial dentures.Int J Periodontics Restorative Dent. 2008 Dec;28(6):593-9. Int J Periodontics Restorative Dent. 2008. PMID: 19146055 Clinical Trial.
-
Immediate occlusal loading of implants in the partially edentate mandible: a prospective 1-year radiographic and 4-year clinical study.Int J Oral Maxillofac Implants. 2008 Mar-Apr;23(2):315-22. Int J Oral Maxillofac Implants. 2008. PMID: 18548929
-
Marginal bone level changes at dental implants after 5 years in function: a meta-analysis.Clin Implant Dent Relat Res. 2011 Mar;13(1):19-28. doi: 10.1111/j.1708-8208.2009.00182.x. Clin Implant Dent Relat Res. 2011. PMID: 19681932 Review.
-
Implant therapy in partially edentulous, periodontally compromised patients: a review.J Clin Periodontol. 2005 May;32(5):506-11. doi: 10.1111/j.1600-051X.2005.00708.x. J Clin Periodontol. 2005. PMID: 15842267 Review.
Cited by
-
Clinical success between tilted and axial implants in edentulous maxilla: A systematic review and meta-analysis.J Indian Prosthodont Soc. 2021 Jul-Sep;21(3):217-228. doi: 10.4103/jips.jips_79_21. J Indian Prosthodont Soc. 2021. PMID: 34380808 Free PMC article.
-
Three-Dimensional Evaluation of Implant Positioning in the Maxillary Sinus Septum: A Retrospective Study.Med Sci Monit. 2015 Sep 8;21:2666-71. doi: 10.12659/MSM.894403. Med Sci Monit. 2015. PMID: 26363865 Free PMC article.
-
In-vitro fatigue and fracture performance of three different ferrulized implant connections used in fixed prosthesis.J Dent Sci. 2021 Jan;16(1):397-403. doi: 10.1016/j.jds.2020.08.002. Epub 2020 Aug 27. J Dent Sci. 2021. PMID: 33384826 Free PMC article.
-
Peri-Implant Behavior of Sloped Shoulder Dental Implants Used for All-On-Four Protocols: An Histomorphometric Analysis in Dogs.Materials (Basel). 2018 Jan 12;11(1):119. doi: 10.3390/ma11010119. Materials (Basel). 2018. PMID: 29329255 Free PMC article.
-
Strains around distally inclined implants retaining mandibular overdentures with Locator attachments: an in vitro study.J Adv Prosthodont. 2016 Apr;8(2):116-24. doi: 10.4047/jap.2016.8.2.116. Epub 2016 Apr 21. J Adv Prosthodont. 2016. PMID: 27141255 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous