Accuracy of ultrasound-guided puncture of the ventricular system
- PMID: 17609966
- DOI: 10.1007/s00381-007-0410-x
Accuracy of ultrasound-guided puncture of the ventricular system
Abstract
Objects: Puncture of the ventricular system as one of the most frequently performed operative procedures in neurosurgery is usually done in a freehand way without guiding devices. The objective of this study is to examine whether ultrasonic guidance is able to heighten the accuracy of ventricular tapping.
Methods: Real-time imaging via a single burr hole approach is achieved by aid of a bajonet-like shaped transducer with a footprint of 8x8 mm only (EUP-NS32, Hitachi Medical Systems). The needle is advanced towards the frontal horn along a displayed guideline. 51 punctures in 48 patients were performed with ultrasonic guidance and compared to 85 punctures in 67 patients without a guiding device.
Conclusion: The presented ultrasound method was not able to heighten the access rate of ventricular tapping, but it improved correct positioning of the catheter tip inside the frontal horn of the ventricular system significantly.
Similar articles
-
Single-Camera Closed-Form Real-Time Needle Tracking for Ultrasound-Guided Needle Insertion.Ultrasound Med Biol. 2015 Oct;41(10):2663-76. doi: 10.1016/j.ultrasmedbio.2015.05.016. Epub 2015 Jul 26. Ultrasound Med Biol. 2015. PMID: 26215491
-
Multipole Magnetic Needle Positioning Method for Ultrasound-Guided Puncture.IEEE Trans Biomed Eng. 2025 Apr;72(4):1397-1409. doi: 10.1109/TBME.2024.3507948. Epub 2025 Mar 21. IEEE Trans Biomed Eng. 2025. PMID: 40030436
-
Ultrasound-guided needle insertion robotic system for percutaneous puncture.Int J Comput Assist Radiol Surg. 2021 Mar;16(3):475-484. doi: 10.1007/s11548-020-02300-1. Epub 2021 Jan 23. Int J Comput Assist Radiol Surg. 2021. PMID: 33484429
-
Three-dimensional ultrasound-guided placement of ventricular catheters.World Neurosurg. 2014 Sep-Oct;82(3-4):536.e5-9. doi: 10.1016/j.wneu.2013.08.021. Epub 2013 Aug 23. World Neurosurg. 2014. PMID: 23973451 Review.
-
[Ultrasound-guided interventions and description of the equipment].Z Gastroenterol. 2010 Nov;48(11):1305-16. doi: 10.1055/s-0029-1245706. Epub 2010 Nov 1. Z Gastroenterol. 2010. PMID: 21043010 Review. German.
Cited by
-
Smartphone-assisted guide for the placement of ventricular catheters.Childs Nerv Syst. 2013 Jan;29(1):131-9. doi: 10.1007/s00381-012-1943-1. Epub 2012 Oct 23. Childs Nerv Syst. 2013. PMID: 23089936
-
Strategic placement of bedside ventriculostomies using ultrasound image guidance: report of three cases.Neurocrit Care. 2012 Oct;17(2):255-9. doi: 10.1007/s12028-011-9571-2. Neurocrit Care. 2012. PMID: 21691896
-
Surgical Performance Determines Functional Outcome Benefit in the Minimally Invasive Surgery Plus Recombinant Tissue Plasminogen Activator for Intracerebral Hemorrhage Evacuation (MISTIE) Procedure.Neurosurgery. 2019 Jun 1;84(6):1157-1168. doi: 10.1093/neuros/nyz077. Neurosurgery. 2019. PMID: 30891610 Free PMC article. Clinical Trial.
-
Guided (VENTRI-GUIDE) versus freehand ventriculostomy: study protocol for a randomized controlled trial.Trials. 2014 Dec 5;15:478. doi: 10.1186/1745-6215-15-478. Trials. 2014. PMID: 25480528 Free PMC article. Clinical Trial.
-
Surgical Performance in Minimally Invasive Surgery Plus Recombinant Tissue Plasminogen Activator for Intracerebral Hemorrhage Evacuation Phase III Clinical Trial.Neurosurgery. 2017 Nov 1;81(5):860-866. doi: 10.1093/neuros/nyx123. Neurosurgery. 2017. PMID: 28402516 Free PMC article. Clinical Trial.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources