Image quality and focal lesion detection on T2-weighted MR imaging of the liver: comparison of two high-resolution free-breathing imaging techniques with two breath-hold imaging techniques
- PMID: 17610287
- DOI: 10.1002/jmri.21002
Image quality and focal lesion detection on T2-weighted MR imaging of the liver: comparison of two high-resolution free-breathing imaging techniques with two breath-hold imaging techniques
Abstract
Purpose: To evaluate image quality and accuracy for the detection of focal hepatic lesions depicted on T2-weighted images obtained with two high-resolution free-breathing techniques (navigator-triggered turbo spin-echo [TSE] and respiratory-triggered TSE) and two standard-resolution breath-hold techniques (breath-hold TSE with restore pulse and half-Fourier acquisition single-shot TSE [HASTE]).
Materials and methods: Our institutional review board approved this study, and written informed consent was obtained from all patients. Two readers independently reviewed 200 T2-weighted imaging sets obtained with four sequences in 50 patients. Both readers identified all focal lesions in session 1 and only solid lesions in session 2. The readers' confidence was graded using a scale of 1-4 (1 <or= 50%; 4 >or= 95%). The diagnostic accuracies of the four MR sequences were evaluated using the free-response receiver operating characteristic (ROC) method. Region-of-interest (ROI) measurements were performed for the mean signal intensity (SI) in the liver, spleen, hepatic lesions, and background noise.
Results: The accuracy of navigator-triggered TSE and respiratory-triggered TSE was superior to that of breath-hold TSE with restore pulse and HASTE for the detection of all focal or solid hepatic lesions. The mean lesion-to-liver contrast-to-noise ratio (CNR) of solid lesions in navigator-triggered (P < 0.001) and respiratory-triggered TSE (P < 0.005) was significantly higher than that in HASTE.
Conclusion: High-resolution, free-breathing, T2-weighted MRI techniques can significantly improve the detectability of focal hepatic lesions and provide higher lesion-to-liver contrast of solid lesions compared to breath-hold techniques.
(c) 2007 Wiley-Liss, Inc.
Similar articles
-
Magnetic resonance imaging of the upper abdomen using a free-breathing T2-weighted turbo spin echo sequence with navigator triggered prospective acquisition correction.J Magn Reson Imaging. 2005 May;21(5):576-82. doi: 10.1002/jmri.20293. J Magn Reson Imaging. 2005. PMID: 15834908
-
Liver T2-weighted MR imaging: comparison of fast and conventional half-Fourier single-shot turbo spin-echo, breath-hold turbo spin-echo, and respiratory-triggered turbo spin-echo sequences.Radiology. 1997 Jun;203(3):766-72. doi: 10.1148/radiology.203.3.9169702. Radiology. 1997. PMID: 9169702
-
Comparison of three free-breathing T2-weighted MRI sequences in the evaluation of focal liver lesions.AJR Am J Roentgenol. 2008 Jan;190(1):W19-27. doi: 10.2214/AJR.07.2043. AJR Am J Roentgenol. 2008. PMID: 18094268
-
[PSIF/CE-FAST (fast gradient echo) and TSE (turbo spin echo)].Nihon Rinsho. 1998 Nov;56(11):2773-7. Nihon Rinsho. 1998. PMID: 9847597 Review. Japanese.
-
Motion artifact control in body MR imaging.Magn Reson Imaging Clin N Am. 1999 May;7(2):289-301. Magn Reson Imaging Clin N Am. 1999. PMID: 10382162 Review.
Cited by
-
Advances in pediatric body MRI.Pediatr Radiol. 2011 Sep;41 Suppl 2(Suppl 2):549-54. doi: 10.1007/s00247-011-2103-6. Epub 2011 Aug 17. Pediatr Radiol. 2011. PMID: 21847737 Free PMC article. Review.
-
Performance of U-net based pyramidal lucas-kanade registration on free-breathing multi-b-value diffusion MRI of the kidney.Br J Radiol. 2018 Jun;91(1086):20170813. doi: 10.1259/bjr.20170813. Epub 2018 Mar 28. Br J Radiol. 2018. PMID: 29528241 Free PMC article.
-
Evaluation of a free-breathing respiratory-triggered (Navigator) 3-D T1-weighted (T1W) gradient recalled echo sequence (LAVA) for detection of enhancement in cystic and solid renal masses.Eur Radiol. 2019 May;29(5):2507-2517. doi: 10.1007/s00330-018-5839-7. Epub 2018 Nov 30. Eur Radiol. 2019. PMID: 30506224
-
Quantitative image quality evaluation of MR images using perceptual difference models.Med Phys. 2008 Jun;35(6):2541-53. doi: 10.1118/1.2903207. Med Phys. 2008. PMID: 18649487 Free PMC article.
-
Application of deep learning techniques for breath-hold, high-precision T2-weighted magnetic resonance imaging of the abdomen.Abdom Radiol (NY). 2025 May;50(5):2312-2320. doi: 10.1007/s00261-024-04675-0. Epub 2024 Nov 13. Abdom Radiol (NY). 2025. PMID: 39535616
MeSH terms
LinkOut - more resources
Full Text Sources
Medical