Discordance between anatomical and functional coronary stenosis severity
- PMID: 17612701
- PMCID: PMC1847721
Discordance between anatomical and functional coronary stenosis severity
Abstract
BACKGROUND.: New developments have made 16-slice multidetector computed tomography (MDCT) a promising technique for detecting significant coronary stenoses. At present, there is a paucity of data on the relation between fractional flow reserve (FFR) measurement and MDCT stenosis detection. OBJECTIVE.: The aim of this study was to investigate the relation between the anatomical severity of coronary artery disease detected by MDCT and functional severity measured by fractional flow reserve (FFR). METHODS.: We studied 53 patients (39 men and 14 women, age 62.5+/-8.1 years) with single-vessel disease scheduled for percutaneous coronary intervention (PCI). All patients underwent MDCT scanning one day prior to PCI and FFR was measured before PCI in the target vessel. RESULTS.: MDCT analysis could be performed in 52 of 53 patients (98.1%) and all patients had adequate FFR and quantitative coronary angiography (QCA) measurements. The mean stenosis diameters calculated by MDCT and QCA were 67.0+/-11.6% and 60.8+/-11.6% respectively. No significant relation was found between MDCT and QCA (r=0.22, p=0.12) The mean FFR in all patients was 0.67+/-0.18. A relation of r=-0.46 (p=0.0006) between QCA and FFR was found. In contrast, no relation between MDCT and FFR could be demonstrated (r=-0.09, p=0.50). Furthermore, a high incidence of false-positive and false-negative findings was present in both diagnostic modalities. CONCLUSION.: There is no clear relation between the anatomical and functional severity of coronary artery disease as defined by MDCT and FFR. Therefore, functional assessment of coronary artery disease remains mandatory for clinical decisionmaking. (Neth Heart J 2007;15:5-11.).
Figures
References
-
- Fischer JJ, Samady H, McPherson JA, et al. Comparison between visual assessment and quantitative angiography versus fractional flow reserve for native coronary narrowings of moderate severity. Am J Cardiol 2002;90:210-5. - PubMed
-
- Kimball BP, Bui S, Cohen EA, Cheung PK, Lima V. Systematic bias in the reporting of angioplasty outcomes: accuracy of visual estimates of absolute lumen diameters. Can J Cardiol 1994;10: 815-20. - PubMed
-
- Reiber JH, van der Zwet PM, Koning G, et al. Accuracy and precision of quantitative digital coronary arteriography: observer-, short-, and medium-term variabilities. Cathet Cardiovasc Diagn 1993;28:187-98. - PubMed
-
- Topol EJ, Nissen SE. Our preoccupation with coronary luminology. The dissociation between clinical and angiographic findings in ischemic heart disease. Circulation 1995;92:2333-42. - PubMed
-
- Zijlstra F, Fioretti P, Reiber JH, Serruys PW. Which cineangiographically assessed anatomic variable correlates best with functional measurements of stenosis severity? A comparison of quantitative analysis of the coronary cineangiogram with measured coronary flow reserve and exercise/redistribution thallium-201 scintigraphy. J Am Coll Cardiol 1988;12:686-91. - PubMed
LinkOut - more resources
Full Text Sources
Miscellaneous