Agreement between methods of measurement with multiple observations per individual
Abstract
Limits of agreement provide a straightforward and intuitive approach to agreement between different methods for measuring the same quantity. When pairs of observations using the two methods are independent, i.e., on different subjects, the calculations are very simple and straightforward. Some authors collect repeated data, either as repeated pairs of measurements on the same subject, whose true value of the measured quantity may be changing, or more than one measurement by one or both methods of an unchanging underlying quantity. In this paper we describe methods for analysing such clustered observations, both when the underlying quantity is assumed to be changing and when it is not.
Comment in
-
Rejoinder to the letter to the editor.J Biopharm Stat. 2019;29(3):576. doi: 10.1080/10543406.2019.1583964. J Biopharm Stat. 2019. PMID: 31116697 No abstract available.
Similar articles
-
Lack of agreement between measurement of ejection fraction by impedance cardiography versus radionuclide ventriculography.Crit Care Med. 1993 Oct;21(10):1523-7. doi: 10.1097/00003246-199310000-00021. Crit Care Med. 1993. PMID: 8403962
-
Measuring agreement in method comparison studies.Stat Methods Med Res. 1999 Jun;8(2):135-60. doi: 10.1177/096228029900800204. Stat Methods Med Res. 1999. PMID: 10501650 Review.
-
Comparison of concordance correlation coefficient and coefficient of individual agreement in assessing agreement.J Biopharm Stat. 2007;17(4):721-38. doi: 10.1080/10543400701329497. J Biopharm Stat. 2007. PMID: 17613650
-
Regression models for method comparison data.J Biopharm Stat. 2007;17(4):739-56. doi: 10.1080/10543400701329513. J Biopharm Stat. 2007. PMID: 17613651
-
Application of impedance cardiography in critical care medicine.Resuscitation. 1984 Mar;11(3-4):255-74. doi: 10.1016/0300-9572(84)90023-6. Resuscitation. 1984. PMID: 6326226 Review.
Cited by
-
Evaluation of Two Commercial ELISA Kits for Measuring Equine Serum Gastrin Compared to Radioimmunoassay.Animals (Basel). 2024 Oct 11;14(20):2937. doi: 10.3390/ani14202937. Animals (Basel). 2024. PMID: 39457867 Free PMC article.
-
A new, effective and low-cost three-dimensional approach for the estimation of upper-limb volume.Sensors (Basel). 2015 May 26;15(6):12342-57. doi: 10.3390/s150612342. Sensors (Basel). 2015. PMID: 26016917 Free PMC article.
-
Validation of the EQ-5D-5L and psychosocial bolt-ons in a large cohort of people living with multiple sclerosis in Australia.Qual Life Res. 2023 Feb;32(2):553-568. doi: 10.1007/s11136-022-03214-y. Epub 2022 Aug 29. Qual Life Res. 2023. PMID: 36036311 Free PMC article.
-
Computer vision for kinematic metrics of the drinking task in a pilot study of neurotypical participants.Sci Rep. 2024 Sep 5;14(1):20668. doi: 10.1038/s41598-024-71470-8. Sci Rep. 2024. PMID: 39237646 Free PMC article.
-
Evaluation of a continuous glucose monitoring system in neonatal foals.J Vet Intern Med. 2021 Jul;35(4):1995-2001. doi: 10.1111/jvim.16186. Epub 2021 Jun 6. J Vet Intern Med. 2021. PMID: 34096103 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical