Comparison of two commercial immunoassays for the detection of anti-rubella IgM and IgG in pediatric patients
- PMID: 17613675
- DOI: 10.1080/15321810701454953
Comparison of two commercial immunoassays for the detection of anti-rubella IgM and IgG in pediatric patients
Abstract
The only threatening modality of rubella is the Congenital Rubella Syndrome that affects fetuses of women who acquire infection during early pregnancy. Laboratory diagnosis is based on serological parameters. We compared anti-rubella IgM and IgG detection of two commercial immunoassay kits (Abbott and Roche). Although we observed an agreement of 97.8% for IgM and 95.7% for IgG when the categories positive, negative and indeterminate were considered, mean titers of IgG and the absorbance/cut off of IgM were statistically different for both kits, thus corroborating the idea that serological results depend very much on the methodology and must be carefully interpreted.
Similar articles
-
[Usefulness of determining low-avidity IgG antibodies in the diagnosis of primary rubella infection in pregnant women].Enferm Infecc Microbiol Clin. 1998 Nov;16(9):413-8. Enferm Infecc Microbiol Clin. 1998. PMID: 9887628 Spanish.
-
Multicentric evaluation of two chemiluminescent immunoassays for IgG and IgM antibodies towards Rubella virus.J Clin Virol. 2010 Oct;49(2):105-10. doi: 10.1016/j.jcv.2010.07.011. Epub 2010 Aug 21. J Clin Virol. 2010. PMID: 20728403
-
Assessment of IgM enzyme immunoassay and IgG avidity assay for distinguishing between primary and secondary immune response to rubella vaccine.J Virol Methods. 2005 Dec;130(1-2):59-65. doi: 10.1016/j.jviromet.2005.06.003. Epub 2005 Jul 18. J Virol Methods. 2005. PMID: 16026863
-
Diagnostic accuracy of commercially available serological tests for the detection of measles and rubella viruses: a systematic review and meta-analysis.J Clin Microbiol. 2024 Feb 14;62(2):e0133923. doi: 10.1128/jcm.01339-23. Epub 2024 Jan 26. J Clin Microbiol. 2024. PMID: 38275299 Free PMC article.
-
Interpretation of rubella serology in pregnancy--pitfalls and problems.BMJ. 2002 Jul 20;325(7356):147-8. doi: 10.1136/bmj.325.7356.147. BMJ. 2002. PMID: 12130613 Free PMC article. Review. No abstract available.
Cited by
-
Results of continuous monitoring of the performance of rubella virus IgG and hepatitis B virus surface antibody assays using trueness controls in a multicenter trial.Clin Vaccine Immunol. 2012 Oct;19(10):1624-32. doi: 10.1128/CVI.00294-12. Epub 2012 Aug 15. Clin Vaccine Immunol. 2012. PMID: 22896686 Free PMC article. Clinical Trial.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical