Practicing paramedics cannot generate or estimate safe endotracheal tube cuff pressure using standard techniques
- PMID: 17613904
- DOI: 10.1080/10903120701348248
Practicing paramedics cannot generate or estimate safe endotracheal tube cuff pressure using standard techniques
Abstract
Objectives: We sought to determine the ability of paramedics to inflate endotracheal tube cuffs within safe pressure limits as well as to estimate the pressure of previously inflated endotracheal tube cuffs by palpation of the pilot balloon.
Methods: Using a tracheal simulation model, we conducted a prospective, observational, cross-sectional simulation study of licensed, practicing paramedics. This included evaluation of their ability to inflate the cuff of an endotracheal tube to a safe pressure, defined as < or = 25 cm H(2)O, as well as to identify excessive intracuff pressure in previously inflated ETT cuffs by palpation of the pilot balloon.
Results: Fifty-three paramedics were sampled. The average pressure generated by inflating the endotracheal tube cuff was > 108 cm H(2)O. Participants were only 13% sensitive detecting over inflated endotracheal tube cuffs (95% CI 7.3-17.8).
Conclusions: Participants were unable to inflate endotracheal tube cuff to safe pressures and were unable to identify endotracheal tube cuffs with excessive intracuff pressure by palpation. Clinicians should consider using devices such as manometers to facilitate safe inflation and accurate measurement of endotracheal tube cuff pressure.
Similar articles
-
Experienced emergency medicine physicians cannot safely inflate or estimate endotracheal tube cuff pressure using standard techniques.Am J Emerg Med. 2006 Mar;24(2):139-43. doi: 10.1016/j.ajem.2005.07.016. Am J Emerg Med. 2006. PMID: 16490640
-
The effect of pilot balloon design on estimation of safe tracheal tube cuff pressure.Anaesthesia. 2010 Aug;65(8):785-91. doi: 10.1111/j.1365-2044.2010.06413.x. Epub 2010 Jun 22. Anaesthesia. 2010. PMID: 20573148
-
Laboratory evaluation of 4 brands of endotracheal tube cuff inflator.Respir Care. 2004 Feb;49(2):166-73. Respir Care. 2004. PMID: 14744266
-
Endotracheal tube cuff leaks: causes, consequences, and management.Anesth Analg. 2013 Aug;117(2):428-34. doi: 10.1213/ANE.0b013e318292ee21. Epub 2013 Jun 6. Anesth Analg. 2013. PMID: 23744958 Review.
-
Review of tracheo-esophageal fistula associated with endotracheal intubation.J Surg Educ. 2007 Jul-Aug;64(4):237-40. doi: 10.1016/j.jsurg.2007.05.004. J Surg Educ. 2007. PMID: 17706579 Review.
Cited by
-
Mapping the use of simulation in prehospital care - a literature review.Scand J Trauma Resusc Emerg Med. 2014 Mar 28;22:22. doi: 10.1186/1757-7241-22-22. Scand J Trauma Resusc Emerg Med. 2014. PMID: 24678868 Free PMC article. Review.
-
[Subjective method for tracheal tube cuff inflation: performance of anesthesiology residents and staff anesthesiologists. Prospective observational study].Braz J Anesthesiol. 2020 Jan-Feb;70(1):9-14. doi: 10.1016/j.bjan.2019.09.010. Epub 2020 Feb 19. Braz J Anesthesiol. 2020. PMID: 32199655 Free PMC article.
-
Is sealing cuff pressure, easy, reliable and safe technique for endotracheal tube cuff inflation?: A comparative study.Saudi J Anaesth. 2011 Apr;5(2):185-9. doi: 10.4103/1658-354X.82795. Saudi J Anaesth. 2011. PMID: 21804801 Free PMC article.
-
Endotracheal Tube Cuff Pressures in Patients Intubated Prior to Helicopter EMS Transport.West J Emerg Med. 2016 Nov;17(6):721-725. doi: 10.5811/westjem.2016.8.30639. Epub 2016 Sep 13. West J Emerg Med. 2016. PMID: 27833679 Free PMC article.
-
Linear correlation of endotracheal tube cuff pressure and volume.West J Emerg Med. 2009 Aug;10(3):137-9. West J Emerg Med. 2009. PMID: 19718371 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources