Abstract
We perform combined magnetic resonance and bioluminescence imaging of live mice for the purpose of improving the accuracy of bioluminescence tomography. The imaging is performed on three live nude mice in which tritium-powered light sources are surgically implanted. High-resolution magnetic resonance images and multispectral, multiview bioluminescence images are acquired in the same session. An anatomical model is constructed by segmenting the magnetic resonance images for all major tissues. The model is subsequently registered with nonlinear transformations to the 3-D light exittance (exiting intensity) surface map generated from the luminescence images. A Monte Carlo algorithm, along with a set of tissue optical properties obtained from in vivo measurements, is used to solve the forward problem. The measured and simulated light exittance images are found to differ by a factor of up to 2. The greatest cause of this moderate discrepancy is traced to the small errors in source positioning, and to a lesser extent to the optical properties used for the tissues. Discarding the anatomy and using a homogeneous model leads to a marginally worse agreement between the simulated and measured data.
Similar articles
-
Registration of planar bioluminescence to magnetic resonance and x-ray computed tomography images as a platform for the development of bioluminescence tomography reconstruction algorithms.J Biomed Opt. 2009 Mar-Apr;14(2):024045. doi: 10.1117/1.3120495. J Biomed Opt. 2009. PMID: 19405773 Free PMC article.
-
In vivo bioluminescence tomography with a blocking-off finite-difference SP3 method and MRI/CT coregistration.Med Phys. 2010 Jan;37(1):329-38. doi: 10.1118/1.3273034. Med Phys. 2010. PMID: 20175496 Free PMC article.
-
Bioluminescence tomography with CT/MRI co-registration.Annu Int Conf IEEE Eng Med Biol Soc. 2009;2009:6327-30. doi: 10.1109/IEMBS.2009.5333170. Annu Int Conf IEEE Eng Med Biol Soc. 2009. PMID: 19964154
-
Whole-body simultaneous positron emission tomography (PET)-MR: optimization and adaptation of MRI sequences.J Magn Reson Imaging. 2014 Feb;39(2):259-68. doi: 10.1002/jmri.24308. Epub 2013 Oct 29. J Magn Reson Imaging. 2014. PMID: 24436150 Review.
-
Looking and listening to light: the evolution of whole-body photonic imaging.Nat Biotechnol. 2005 Mar;23(3):313-20. doi: 10.1038/nbt1074. Nat Biotechnol. 2005. PMID: 15765087 Review.
Cited by
-
Recent methodology advances in fluorescence molecular tomography.Vis Comput Ind Biomed Art. 2018 Sep 5;1(1):1. doi: 10.1186/s42492-018-0001-6. Vis Comput Ind Biomed Art. 2018. PMID: 32240398 Free PMC article. Review.
-
Co-Registration of Bioluminescence Tomography, Computed Tomography, and Magnetic Resonance Imaging for Multimodal In Vivo Stem Cell Tracking.Tomography. 2016 Jun;2(2):159-165. doi: 10.18383/j.tom.2016.00160. Tomography. 2016. PMID: 27478872 Free PMC article.
-
Quantitative molecular bioluminescence tomography.J Biomed Opt. 2022 Jun;27(6):066004. doi: 10.1117/1.JBO.27.6.066004. J Biomed Opt. 2022. PMID: 35726130 Free PMC article.
-
Registration of planar bioluminescence to magnetic resonance and x-ray computed tomography images as a platform for the development of bioluminescence tomography reconstruction algorithms.J Biomed Opt. 2009 Mar-Apr;14(2):024045. doi: 10.1117/1.3120495. J Biomed Opt. 2009. PMID: 19405773 Free PMC article.
-
In vivo quantitative bioluminescence tomography using heterogeneous and homogeneous mouse models.Opt Express. 2010 Jun 7;18(12):13102-13. doi: 10.1364/OE.18.013102. Opt Express. 2010. PMID: 20588440 Free PMC article.