Ambient air monitoring with Auto-gas chromatography running in trigger mode
- PMID: 17616253
- DOI: 10.1016/j.aca.2007.05.058
Ambient air monitoring with Auto-gas chromatography running in trigger mode
Abstract
Speciated volatile organic compounds (VOC), either as ozone precursors or air toxics in the air, are commonly monitored by triggered canister method or continuous ozone precursor analyzer (commonly known as Auto-gas chromatography (GC)) method. In the triggered canister method, a canister sample is collected when a total non-methane organic compound (TNMOC) concentration exceeds a pre-determined trigger level. The canister sample is then analyzed in a lab in a later time. In the Auto-GC method, an online GC runs in a "continuous" mode with a sampling and analysis cycle of 1 h. Within the cycle hour, samples are collected only during the first 40 min. A new approach of Auto-GC running in trigger mode is developed in this study. This new approach uses Auto-GC but operates it in a trigger mode similar to the triggered canister sampling method. Compared to the triggered canister sample method, this system provides near real-time speciated VOC data, which are critical for responding to a high VOC concentration episode. Although the canister system generally costs less, its cost advantage may diminish if trigger events are frequent and the monitoring duration is long. Compared to continuous Auto-GC, triggered GC has its niche--it is better for capturing transient plumes with a small footprint. The continuous GC either misses a transient plume if the plume does not arrive at the sampling site during the sampling cycle or flattens the plume concentration peak by dilution with non-plume air sample. Field experience with this system for fenceline VOC monitoring is presented. The sampling and calibration strategy for trigger mode operation is described. The chromatograph retention time drift issues are discussed. The system performance is evaluated, including the method detection limit, precision and accuracy. The trigger mode configuration for VOC fenceline or near source monitoring in this work proved effective for local and transient plume identification.
Similar articles
-
A novel personal air sampling device for collecting volatile organic compounds: a comparison to charcoal tubes and diffusive badges.J Occup Environ Hyg. 2004 Feb;1(2):69-81. doi: 10.1080/15459620490275542. J Occup Environ Hyg. 2004. PMID: 15204881
-
Characterization of industrial plumes of volatile organic compounds by guided sampling.Chemosphere. 2020 Feb;241:124957. doi: 10.1016/j.chemosphere.2019.124957. Epub 2019 Sep 24. Chemosphere. 2020. PMID: 31590021
-
Sampling, storage, and analysis of C2-C7 non-methane hydrocarbons from the US National Oceanic and Atmospheric Administration Cooperative Air Sampling Network glass flasks.J Chromatogr A. 2008 Apr 25;1188(2):75-87. doi: 10.1016/j.chroma.2008.02.059. Epub 2008 Mar 10. J Chromatogr A. 2008. PMID: 18355832
-
Assessment of ambient air quality in Eskişehir, Turkey.Environ Int. 2008 Jul;34(5):678-87. doi: 10.1016/j.envint.2007.12.016. Epub 2008 Mar 4. Environ Int. 2008. PMID: 18291527
-
Construction of an automated gas chromatography/mass spectrometry system for the analysis of ambient volatile organic compounds with on-line internal standard calibration.J Chromatogr A. 2008 Aug 8;1201(2):134-40. doi: 10.1016/j.chroma.2008.03.071. Epub 2008 Mar 29. J Chromatogr A. 2008. PMID: 18405905
LinkOut - more resources
Full Text Sources
Miscellaneous