Models of the human brain and the surrounding media: their influence on the reliability of source localization
- PMID: 1761704
- DOI: 10.1097/00004691-199110000-00003
Models of the human brain and the surrounding media: their influence on the reliability of source localization
Abstract
This article is a review of the evolution of models of the head as used in dipole source localization. Models fall into two classes: those that can be expressed in simple analytic form, such as the homogeneous sphere or spherical three-shell models, or those that can only be solved by numerical methods, such as the finite element approach. The latter models always involve heavy procedural and computational burdens. The trend over the last decade has been to use these more advanced models to estimate the error that would be incurred if one of the simpler spherical models were used instead for dipole source localization. An estimate is presented of the magnitudes of the random and systematic errors of localization that may be expected when using these methods.
Similar articles
-
Evaluation of multiple-sphere head models for MEG source localization.Phys Med Biol. 2011 Sep 7;56(17):5621-35. doi: 10.1088/0031-9155/56/17/010. Epub 2011 Aug 9. Phys Med Biol. 2011. PMID: 21828900
-
Conventional and reciprocal approaches to the inverse dipole localization problem of electroencephalography.IEEE Trans Biomed Eng. 2003 Jun;50(6):657-66. doi: 10.1109/TBME.2003.812198. IEEE Trans Biomed Eng. 2003. PMID: 12814232
-
Dipole models for the EEG and MEG.IEEE Trans Biomed Eng. 2002 May;49(5):409-18. doi: 10.1109/10.995679. IEEE Trans Biomed Eng. 2002. PMID: 12002172
-
Forward and inverse problems of EEG dipole localization.Crit Rev Biomed Eng. 1999;27(3-5):189-239. Crit Rev Biomed Eng. 1999. PMID: 10864280 Review.
-
Development of volume conductor and source models to localize epileptic foci.J Clin Neurophysiol. 2007 Apr;24(2):101-19. doi: 10.1097/WNP.0b013e318038fb3e. J Clin Neurophysiol. 2007. PMID: 17414966 Review.
Cited by
-
Effects of tissue resistivities on electroencephalogram sensitivity distribution.Med Biol Eng Comput. 1999 Sep;37(5):555-9. doi: 10.1007/BF02513348. Med Biol Eng Comput. 1999. PMID: 10723891
-
Source analysis of median nerve and finger stimulated somatosensory evoked potentials: multichannel simultaneous recording of electric and magnetic fields combined with 3D-MR tomography.Brain Topogr. 1994 Summer;6(4):299-310. doi: 10.1007/BF01211175. Brain Topogr. 1994. PMID: 7946929 Clinical Trial.
-
Comparison of realistically shaped boundary-element and spherical head models in source localization of early somatosensory evoked potentials.Brain Topogr. 1995 Winter;8(2):137-43. doi: 10.1007/BF01199777. Brain Topogr. 1995. PMID: 8793124
-
Thickness and resistivity variations over the upper surface of the human skull.Brain Topogr. 1993 Winter;6(2):99-109. doi: 10.1007/BF01191074. Brain Topogr. 1993. PMID: 8123431
-
Source model and scalp topography of pattern reversal visual evoked potentials to altitudinal stimuli suggest that infoldings of calcarine fissure are not part of VEP generators.Brain Topogr. 1995 Spring;7(3):217-31. doi: 10.1007/BF01202381. Brain Topogr. 1995. PMID: 7599021
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources