Microfluidic systems integrated with two-dimensional surface plasmon resonance phase imaging systems for microarray immunoassay
- PMID: 17618110
- DOI: 10.1016/j.bios.2007.05.007
Microfluidic systems integrated with two-dimensional surface plasmon resonance phase imaging systems for microarray immunoassay
Abstract
This study reports a microfluidic chip integrated with an arrayed immunoassay for surface plasmon resonance (SPR) phase imaging of specific bio-samples. The SPR phase imaging system uses a surface-sensitive optical technique to detect two-dimensional (2D) spatial phase variation caused by rabbit immunoglobulin G (IgG) adsorbed on an anti-rabbit IgG film. The microfluidic chip was fabricated by using micro-electro-mechanical-systems (MEMS) technology on glass and polydimethylsiloxane (PDMS) substrates to facilitate well-controlled and reproducible sample delivery and detection. Since SPR detection is very sensitive to temperature variation, a micromachine-based temperature control module comprising micro-heaters and temperature sensors was used to maintain a uniform temperature distribution inside the arrayed detection area with a variation of less than 0.3 degrees C. A self-assembled monolayer (SAM) technique was used to pattern the surface chemistry on a gold layer to immobilize anti-rabbit IgG on the modified substrates. The microfluidic chip is capable of transporting a precise amount of IgG solution by using micropumps/valves to the arrayed detection area such that highly sensitive, highly specific bio-sensing can be achieved. The developed microfluidic chips, which employed SPR phase imaging for immunoassay analysis, could successfully detect the interaction of anti-rabbit IgG and IgG. The interactions between immobilized anti-rabbit IgG and IgG with various concentrations have been measured. The detection limit is experimentally found to be 1 x 10(-4)mg/ml (0.67 nM). The specificity of the arrayed immunoassay was also explored. Experimental data show that only the rabbit IgG can be detected and the porcine IgG cannot be adsorbed. The developed microfluidic system is promising for various applications including medical diagnostics, microarray detection and observing protein-protein interactions.
Similar articles
-
Localized surface plasmon resonance biosensor integrated with microfluidic chip.Biomed Microdevices. 2009 Aug;11(4):893-901. doi: 10.1007/s10544-009-9306-8. Biomed Microdevices. 2009. PMID: 19353272
-
Automatic bio-sampling chips integrated with micro-pumps and micro-valves for disease detection.Biosens Bioelectron. 2005 Sep 15;21(3):419-25. doi: 10.1016/j.bios.2004.11.004. Epub 2004 Dec 15. Biosens Bioelectron. 2005. PMID: 16076430
-
A surface plasmon resonance sensor on a compact disk-type microfluidic device.J Sep Sci. 2011 Oct;34(20):2913-9. doi: 10.1002/jssc.201100446. Epub 2011 Sep 16. J Sep Sci. 2011. PMID: 21928434
-
Surface plasmon resonance biosensing.Methods Mol Biol. 2009;503:65-88. doi: 10.1007/978-1-60327-567-5_5. Methods Mol Biol. 2009. PMID: 19151937 Review.
-
Surface plasmon resonance imaging for affinity-based biosensors.Biosens Bioelectron. 2010 Jan 15;25(5):957-66. doi: 10.1016/j.bios.2009.08.039. Epub 2009 Sep 2. Biosens Bioelectron. 2010. PMID: 19765967 Review.
Cited by
-
Automated analytical microarrays: a critical review.Anal Bioanal Chem. 2008 Jul;391(5):1521-44. doi: 10.1007/s00216-008-2039-3. Epub 2008 May 27. Anal Bioanal Chem. 2008. PMID: 18504563 Free PMC article. Review.
-
Microfluidics Integrated Biosensors: A Leading Technology towards Lab-on-a-Chip and Sensing Applications.Sensors (Basel). 2015 Dec 1;15(12):30011-31. doi: 10.3390/s151229783. Sensors (Basel). 2015. PMID: 26633409 Free PMC article. Review.
-
Optical Detection of Cancer Cells Using Lab-on-a-Chip.Biosensors (Basel). 2023 Mar 30;13(4):439. doi: 10.3390/bios13040439. Biosensors (Basel). 2023. PMID: 37185514 Free PMC article. Review.
-
Soft lithography for micro- and nanoscale patterning.Nat Protoc. 2010 Mar;5(3):491-502. doi: 10.1038/nprot.2009.234. Epub 2010 Feb 18. Nat Protoc. 2010. PMID: 20203666
-
Backscattering particle immunoassays in wire-guide droplet manipulations.J Biol Eng. 2008 Nov 17;2:15. doi: 10.1186/1754-1611-2-15. J Biol Eng. 2008. PMID: 19014703 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources