Five-year results of implants with an oxidized surface placed predominantly in soft quality bone and subjected to immediate occlusal loading
- PMID: 17618935
- DOI: 10.1016/S0022-3913(07)60009-2
Five-year results of implants with an oxidized surface placed predominantly in soft quality bone and subjected to immediate occlusal loading
Erratum in
- J Prosthet Dent. 2008 Mar;99(3):167
Abstract
Statement of problem: Numerous studies have demonstrated the feasibility and predictability of immediate implant loading or immediate implant restoration. However, most of these studies report primarily short-term outcomes.
Purpose: The purpose of this prospective clinical study was to document the 5-year outcome of immediate occlusally loaded implants with an oxidized, microtextured surface placed to support fixed prostheses in various regions of the jaws.
Material and methods: Thirty-eight patients received a total of 51 implant-supported fixed prostheses, 29 mandibular and 22 maxillary, the day of implant insertion. Thirty were fixed partial dentures (FPDs), 20 replaced single teeth, and 1 was a fixed mandibular complete denture. The restorations were supported by 102 slightly tapered, screw-type implants, the majority of which were placed in posterior regions (88%) and primarily in soft bone quality (76%). Patients with ongoing signs of parafunctional habits were not included. All implants were placed using conventional flap procedures. Treatment with local regenerative procedures in connection with implant placement was accepted within the study design. Resonance frequency implant stability measurements and marginal periimplant soft tissue evaluations were conducted. Radiographic examinations were performed at the time of prosthesis insertion, at 1-and 6-month follow-ups, and annually at the 1- through 5-year follow-up visits. This report presents the results after 5 years of loading, summarized with descriptive statistics.
Results: Three maxillary implants were removed, although stable, in 1 patient at the 8-week follow-up due to postoperative infection in the adjacent guided bone regeneration (GBR) area. No additional implants were lost. This resulted in a cumulative implant success rate of 97.1% after 5 years of prosthetic loading. The mean marginal bone remodeling (SD) after 5 years of function was 1.54 (0.99) mm. At the 5-year examination, absence of marginal plaque and absence of bleeding on probing was reported for 75% and 74% of the sites, respectively, and remained generally unchanged from the 1-month follow-up.
Conclusions: The 5-year follow-up data indicate that an immediate loading protocol using a slightly tapered implant design with an oxidized, microtextured surface is a successful treatment alternative in regions exhibiting soft bone quality.
Similar articles
-
Immediate function with fixed implant-supported maxillary dentures: a 12-month pilot study.J Prosthet Dent. 2008 May;99(5):351-60. doi: 10.1016/S0022-3913(08)60082-7. J Prosthet Dent. 2008. PMID: 18456046
-
Immediate occlusal loading of Brånemark System TiUnite implants placed predominantly in soft bone: 4-year results of a prospective clinical study.Clin Implant Dent Relat Res. 2005;7 Suppl 1:S52-9. doi: 10.1111/j.1708-8208.2005.tb00075.x. Clin Implant Dent Relat Res. 2005. PMID: 16137088 Clinical Trial.
-
Report of a case receiving full-arch rehabilitation in both jaws using immediate implant loading protocols: a 1-year resonance frequency analysis follow-up.Clin Implant Dent Relat Res. 2006;8(1):25-31. doi: 10.2310/j.6480.2005.00027.x. Clin Implant Dent Relat Res. 2006. PMID: 16681490
-
Early and immediately restored and loaded dental implants for single-tooth and partial-arch applications.Int J Oral Maxillofac Implants. 2004;19 Suppl:92-102. Int J Oral Maxillofac Implants. 2004. PMID: 15635949 Review.
-
Outcome analysis of implant restorations located in the anterior maxilla: a review of the recent literature.Int J Oral Maxillofac Implants. 2004;19 Suppl:30-42. Int J Oral Maxillofac Implants. 2004. PMID: 15635944 Review.
Cited by
-
Hydroxyapatite Nanorod-Modified Sand Blasted Titanium Disk for Endosseous Dental Implant Applications.Tissue Eng Regen Med. 2018 Aug 25;15(5):601-614. doi: 10.1007/s13770-018-0151-9. eCollection 2018 Oct. Tissue Eng Regen Med. 2018. PMID: 30603582 Free PMC article.
-
Reality of dental implant surface modification: a short literature review.Open Biomed Eng J. 2014 Oct 31;8:114-9. doi: 10.2174/1874120701408010114. eCollection 2014. Open Biomed Eng J. 2014. PMID: 25400716 Free PMC article.
-
Clinical and Radiographic Evaluation of Brånemark Implants with an Anodized Surface following Seven-to-Eight Years of Functional Loading.Int J Dent. 2013;2013:583567. doi: 10.1155/2013/583567. Epub 2013 Mar 7. Int J Dent. 2013. PMID: 23533412 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials