R Schwab et al. Surg Endosc. 2008 Mar.

Abstract

Background: Reliable laparoscopic fixation of meshes prior to their fibrous incorporation is intended to minimize recurrences following transabdominal preperitoneal hernia repair (TAPP) and totally extraperitoneal repair (TEP) repair of inguinal hernias. However, suture-, tack- and staple-based fixation systems are associated with postoperative chronic inguinal pain. Initial fixation with fibrin sealant offers an atraumatic alternative, but there is little data demonstrating directly whether fibrin-based mesh adhesion provides adequate biomechanical stability for repair of inguinal hernia by TAPP and TEP.

Methods: Using a newly developed, standardized simulation model for abdominal wall hernias, sublay repairs were performed with six different types of commercially available hernia mesh. The biomechanical stability achieved, and the protection afforded by the mesh-hernia overlap, were compared for three different techniques: nonfixation, point-by-point suture fixation, and fibrin sealant fixation.

Results: Mesh dislocation from the repaired hernia defect was consistently seen with nonfixation. This was reliably prevented with all six mesh types when fixed using either sutures or fibrin sealant. The highest stress resistance across the whole abdominal wall was found following superficial fixation with fibrin sealant across the mesh types. There was a highly statistically significant improvement in fixation stability with fibrin sealant versus fixation using eight single sutures (p = 0.008), as assessed by the range of achievable peak pressure stress up to 200 mmHg.

Conclusions: To ensure long-term freedom from recurrence, intraoperative mesh-hernia overlap must be retained. This can be achieved with fibrin sealant up to the incorporation of the mesh - without trauma and with biomechanical stability.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Br J Surg. 2002 Nov;89(11):1476-9 - PubMed
    1. Langenbecks Arch Surg. 1999 Feb;384(1):71-5 - PubMed
    1. N Engl J Med. 2004 Apr 29;350(18):1819-27 - PubMed
    1. Hernia. 2005 Dec;9(4):322-9 - PubMed
    1. Br J Surg. 1999 Dec;86(12):1528-31 - PubMed

Publication types

Substances

LinkOut - more resources