Optimization of extraction chromatography separations of trace levels of actinides with ICP-MS detection
- PMID: 17623439
- DOI: 10.1002/jssc.200600513
Optimization of extraction chromatography separations of trace levels of actinides with ICP-MS detection
Abstract
The separation of trace level actinides has been evaluated on extraction chromatography columns. Detection of the actinides was achieved through the use of an inductively coupled plasma MS (ICP-MS). The columns that we tested were prepared from a commercial TRU resin. The separation of the actinides was optimized for several parameters including particle size, column length, packing pressure, and eluent flow rate. We also examined the possibility of reducing or eliminating oxalic acid in the eluents in order to improve the performance of the mass spectrometer. We were able to separate a mixture of five actinides ((232)Th,( 238)U,( 237)Np, (239)Pu,( 243)Am) in less than 4 min. This work has application to rapid bioassay as well as for automated separations of actinide materials.
Similar articles
-
Rapid determination of actinides in urine by inductively coupled plasma mass spectrometry and alpha spectrometry: a hybrid approach.Talanta. 2009 Nov 15;80(1):143-50. doi: 10.1016/j.talanta.2009.06.041. Epub 2009 Jun 24. Talanta. 2009. PMID: 19782204
-
Separation of actinides using capillary extraction chromatography-inductively coupled plasma mass spectrometry.J Chromatogr Sci. 2009 Aug;47(7):545-8. doi: 10.1093/chromsci/47.7.545. J Chromatogr Sci. 2009. PMID: 19772724
-
Ultra low-level measurements of actinides by sector field ICP-MS.Appl Radiat Isot. 2004 Feb-Apr;60(2-4):561-6. doi: 10.1016/j.apradiso.2003.11.083. Appl Radiat Isot. 2004. PMID: 14987704
-
An Overview of Analytical Methods for in Vitro Bioassay of Actinides.Health Phys. 2019 May;116(5):694-714. doi: 10.1097/HP.0000000000000982. Health Phys. 2019. PMID: 30908319 Review.
-
Inductively coupled plasma mass spectrometry (ICP MS): a versatile tool.J Mass Spectrom. 2007 Apr;42(4):419-27. doi: 10.1002/jms.1206. J Mass Spectrom. 2007. PMID: 17385793 Review.
Cited by
-
High-Throughput Determination of Ultratrace Actinides in Urine by In-Line Extraction Chromatography Combined with Quadrupole Inductively Coupled Plasma Mass Spectrometry (EC-ICP-MS).Anal Chem. 2022 Dec 27;94(51):18042-18049. doi: 10.1021/acs.analchem.2c04458. Epub 2022 Dec 15. Anal Chem. 2022. PMID: 36519576 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous