On rendering continuous glucose monitoring ready for prime time in the cardiac care unit
- PMID: 17627191
- DOI: 10.1097/MCA.0b013e328224bb02
On rendering continuous glucose monitoring ready for prime time in the cardiac care unit
Abstract
Background: Although stringent glycemic control is beneficial for patients with diabetes who are hospitalized in a Cardiac Care Unit (CCU), implementation is difficult in part because of the imperative to avoid hypogolycemia with its particularly deleterious consequences in this setting. We therefore explored the potential value of use of a continuous glucose monitoring system to enhance glycemic control in the CCU and sought to identify pitfalls that could be overcome to increase its utility.
Method: This study was performed with a continuous glucose monitoring system (CGMS) manufactured by MiniMed (Northridge, California, USA), a division of Medtronic, Inc. The device used was originally designed for home use and was a prototype. Twenty patients with elevated concentrations of blood glucose who were hospitalized in our CCU were studied after randomization to standard care for diabetes or standard care supplemented by use of a CGMS.
Results: To optimize glycemic control, the need for favorable modifications in the prototype device initially designed for home use were identified and implemented as were the value of intense in-service training of nurses and optimal interactions with patients and their families.
Conclusions: Use of the CGMS was found to be helpful to nursing personnel. Acceptance of the use of the device, however, was contingent upon enabling patients to overcome fear underlying their often subconscious resistance to the use of insulin in the CCU by emphasizing differentiation of such usage from an increased probability of insulin dependence after recovery.
Similar articles
-
An overview and commentary on retrospective, continuous glucose monitoring for the optimisation of care for people with diabetes.Curr Med Res Opin. 2009 Oct;25(10):2389-400. doi: 10.1185/03007990903094452. Curr Med Res Opin. 2009. PMID: 19650750 Review.
-
Glucose control in the intensive care unit.Crit Care Med. 2009 May;37(5):1769-76. doi: 10.1097/CCM.0b013e3181a19ceb. Crit Care Med. 2009. PMID: 19325461 Review.
-
Continuous Subcutaneous Glucose Monitoring System in diabetic mothers during labour and postnatal glucose adaptation of their infants.Diabet Med. 2008 Apr;25(4):450-4. doi: 10.1111/j.1464-5491.2008.02416.x. Diabet Med. 2008. PMID: 18387079
-
A comparison between EASI system 12-lead ECGs and standard 12-lead ECGs for improved clinical nursing practice.J Clin Nurs. 2008 Feb;17(3):370-7. doi: 10.1111/j.1365-2702.2007.01935.x. J Clin Nurs. 2008. PMID: 18205693
-
Continuous glucose monitoring in cystic fibrosis patients according to the glucose tolerance.Horm Metab Res. 2008 Jul;40(7):502-6. doi: 10.1055/s-2008-1062723. Epub 2008 Apr 14. Horm Metab Res. 2008. PMID: 18415892 Clinical Trial.
Cited by
-
Continuous glucose monitoring systems for type 1 diabetes mellitus.Cochrane Database Syst Rev. 2012 Jan 18;1(1):CD008101. doi: 10.1002/14651858.CD008101.pub2. Cochrane Database Syst Rev. 2012. PMID: 22258980 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical