Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2007 Aug;30(4):612.
doi: 10.1007/s10545-007-0635-6. Epub 2007 Jul 12.

Quantification of N-acetylaspartic acid in urine by LC-MS/MS for the diagnosis of Canavan disease

Affiliations

Quantification of N-acetylaspartic acid in urine by LC-MS/MS for the diagnosis of Canavan disease

O Y Al-Dirbashi et al. J Inherit Metab Dis. 2007 Aug.

Abstract

Canavan disease is an autosomal recessive leukodystrophy characterized by excessive excretion of N-acetylaspartic acid (NAA) in urine. The disease is caused by deficiency of aspartoacylase, the enzyme responsible for the hydrolysis of NAA into acetate and l-aspartate. Patients, who are often asymptomatic in their early months, show a wide spectrum of clinical presentation thereafter that includes macrocephaly, poor head control, seizures, abnormal muscle tone, optic atrophy, significant developmental delay and death. In this work, we describe a simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of NAA in urine. The internal standard d3-NAA was added to untreated urine and the mixture was injected into the LC-MS/MS system operated in the negative ion mode. Detection was achieved in multiple reaction monitoring (MRM) mode by monitoring m/z 174 --> 88, 174 --> 130 and 174 --> 58 for NAA and 177 --> 89 for the internal standard. Separation was carried out on a C8 column (2.1 x 150 mm) using a mixture of acetonitrile and water (1:1 v/v) containing 0.05% formic acid at a flow rate of 0.25 ml/min. NAA was eluted at 1.6 min and the run time was approximately 2 min. Using spiked urine, the assay was linear up to 2 mmol/L with limit of quantification at 1 micromol/L (S/N = 12). NAA in patients' urine (n = 17) ranged between 366 and 21,235 mmol/mol creatinine compared to controls of <39 mmol/mol creatinine (n = 159). This LC-MS/MS method for NAA as described involved no extraction and no derivatization, showed no interference, and gave excellent recovery with low variability and short analytical time.

PubMed Disclaimer

LinkOut - more resources