Comparison of two methods (left carotid artery and abdominal aorta) for surgical implantation of radiotelemetry devices in CD-1 mice
- PMID: 17640466
- DOI: 10.1258/002367707781282839
Comparison of two methods (left carotid artery and abdominal aorta) for surgical implantation of radiotelemetry devices in CD-1 mice
Abstract
The goal of this study was to compare two surgical methods, the left carotid (LC) and the abdominal aorta (AA), for mouse instrumentation with telemetry devices, to determine the best method for measuring cardiovascular (CV) parameters by radiotelemetry in freely moving mice. Surgery success rate, postsurgical recovery rate, clinical parameters, CV data (baseline and response to nicotine) and circadian rhythm measurements were compared between these techniques. Brains of LC-implanted mice were evaluated for potential ischaemia by direct observation of the Circle of Willis anatomy and histopathology. For this purpose, a total of 31 CD-1 male mice were instrumented with PA C20 devices (10 with LC and 21 with AA). Mortality, morbidity, physical examination, body weight (BW), water and food consumption (W/FC), mean blood pressure (MBP) and heart rate (HR) were monitored daily during the recovery period (10 days). CV baseline data were recorded continuously during two periods of four days, and finally, both LC- and AA-implanted mice received an acute subcutaneous administration of 1 mg/kg nicotine; BP and HR were recorded during 5 h after nicotine administration. Results showed that, in LC-implanted mice, 80% survived surgery and recovered well. In contrast, only 57% of mice implanted with the AA technique survived surgery and some presented lethal complications. Both techniques had similar recovery times for BW and W/FC, comparable return to normal circadian rhythm (day 6 post-surgery) and similar CV baseline values. No significant differences were observed in CV response to nicotine between both groups of implanted CD-1 mice. No histopathological changes suggestive of ischaemia were noted in the brain of mice implanted in the LC. Six out of the eight LC-implanted mice remained in good health and had good pressure signal for at least 100 days post-surgery, while most of the AA-implanted mice lost the signal pressure within 14-49 days post-surgery. In conclusion, we believe that LC implantation in mice is superior to the AA technique and is more appropriate for long-term telemetry studies, especially for smaller (transgenic) animals.
Similar articles
-
Blood pressure and heart rate determination by radiotelemetry in mice.J Gravit Physiol. 2001 Jul;8(1):P61-2. J Gravit Physiol. 2001. PMID: 12638626
-
Intraperitoneal versus subcutaneous telemetry devices in young Mongolian gerbils (Meriones unguiculatus).Lab Anim. 2007 Apr;41(2):262-9. doi: 10.1258/002367707780378177. Lab Anim. 2007. PMID: 17430626 Clinical Trial.
-
Timecourse of recovery after surgical intraperitoneal implantation of radiotelemetry transmitters in rats.J Pharmacol Toxicol Methods. 2007 Sep-Oct;56(2):218-22. doi: 10.1016/j.vascn.2007.04.006. Epub 2007 May 24. J Pharmacol Toxicol Methods. 2007. PMID: 17596971
-
Direct blood pressure monitoring in laboratory rodents via implantable radio telemetry.Methods Mol Biol. 2009;573:57-73. doi: 10.1007/978-1-60761-247-6_4. Methods Mol Biol. 2009. PMID: 19763922 Review.
-
Safety and nutritional assessment of GM plants and derived food and feed: the role of animal feeding trials.Food Chem Toxicol. 2008 Mar;46 Suppl 1:S2-70. doi: 10.1016/j.fct.2008.02.008. Epub 2008 Feb 13. Food Chem Toxicol. 2008. PMID: 18328408 Review.
Cited by
-
Differences in postsurgical recovery of CF1 mice after intraperitoneal implantation of radiotelemetry devices through a midline or flank surgical approach.J Am Assoc Lab Anim Sci. 2011 Mar;50(2):227-37. J Am Assoc Lab Anim Sci. 2011. PMID: 21439217 Free PMC article.
-
Male prairie voles display cardiovascular dipping associated with an ultradian activity cycle.Physiol Behav. 2016 Mar 15;156:106-16. doi: 10.1016/j.physbeh.2016.01.012. Epub 2016 Jan 15. Physiol Behav. 2016. PMID: 26780151 Free PMC article.
-
Hemodynamic and behavioral differences after administration of meloxicam, buprenorphine, or tramadol as analgesics for telemeter implantation in mice.J Am Assoc Lab Anim Sci. 2013 Sep;52(5):560-6. J Am Assoc Lab Anim Sci. 2013. PMID: 24041211 Free PMC article.
-
Does Tail-Cuff Plethysmography Provide a Reliable Estimate of Central Blood Pressure in Mice?J Am Heart Assoc. 2017 Jun 27;6(6):e006554. doi: 10.1161/JAHA.117.006554. J Am Heart Assoc. 2017. PMID: 28655736 Free PMC article. No abstract available.
-
Growth hormone secretagogue receptor deficiency in mice protects against obesity-induced hypertension.Physiol Rep. 2014 Mar 20;2(3):e00240. doi: 10.1002/phy2.240. Print 2014. Physiol Rep. 2014. PMID: 24760503 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous