Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2007 Aug 14;116(7):755-63.
doi: 10.1161/CIRCULATIONAHA.107.698258. Epub 2007 Jul 23.

Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis

Affiliations

Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis

John G Webb et al. Circulation. .

Abstract

Background: Percutaneous aortic valve replacement represents an endovascular alternative to conventional open heart surgery without the need for sternotomy, aortotomy, or cardiopulmonary bypass.

Methods and results: Transcatheter implantation of a balloon-expandable stent valve using a femoral arterial approach was attempted in 50 symptomatic patients with severe aortic stenosis in whom there was a consensus that the risks of conventional open heart surgery were very high. Valve implantation was successful in 86% of patients. Intraprocedural mortality was 2%. Discharge home occurred at a median of 5 days (interquartile range, 4 to 13). Mortality at 30 days was 12% in patients in whom the logistic European System for Cardiac Operative Risk Evaluation risk score was 28%. With experience, procedural success increased from 76% in the first 25 patients to 96% in the second 25 (P=0.10), and 30-day mortality fell from 16% to 8% (P=0.67). Successful valve replacement was associated with an increase in echocardiographic valve area from 0.6+/-0.2 to 1.7+/-0.4 cm2. Mild paravalvular regurgitation was common but was well tolerated. After valve insertion, there was a significant improvement in left ventricular ejection fraction (P<0.0001), mitral regurgitation (P=0.01), and functional class (P<0.0001). Improvement was maintained at 1 year. Structural valve deterioration was not observed with a median follow-up of 359 days.

Conclusions: Percutaneous valve replacement may be an alternative to conventional open heart surgery in selected high-risk patients with severe symptomatic aortic stenosis.

PubMed Disclaimer

Similar articles

Cited by

Publication types