Percutaneous large-needle aspiration biopsy histology of palpable thyroid nodules: technical and diagnostic performance
- PMID: 17650219
- DOI: 10.1111/j.1365-2559.2007.02764.x
Percutaneous large-needle aspiration biopsy histology of palpable thyroid nodules: technical and diagnostic performance
Abstract
Aim: To report original and review existing data on safety and performance of large-needle aspiration biopsy (LNAB) histology in the preoperative selection of palpable thyroid nodule.
Methods and results: The English literature and original data were reviewed or analysed. The literature on LNAB of thyroid nodules did not report any complications. A study on needle dimensions has explained why LNAB obtains more tissue than fine-needle aspiration (FNA) and is safe. LNAB histology has higher specificity than FNA cytology and markedly reduces the number of inadequate and indeterminate FNA findings. A comparison of 150 FNA-derived cell blocks with 200 LNAB-derived histological blocks after galectin-3 determination in a large nationwide (Italian) study has shown that one to two sections in 10% of the FNA cell blocks and at least five sections in 90% of the LNAB blocks were available for further determinations of thyroid tumour markers.
Conclusion: LNAB merits further consideration for the preoperative selection of thyroid nodules.
Similar articles
-
Galectin-3 detection on large-needle aspiration biopsy improves preoperative selection of thyroid nodules: a prospective cohort study.Ann Med. 2010;42(1):70-8. doi: 10.3109/07853890903439778. Ann Med. 2010. PMID: 20001505
-
The role of large-needle aspiration biopsy in the preoperative selection of palpable thyroid nodules: a summary of principal data.Biomed Pharmacother. 2000 Jul;54(6):350-3. doi: 10.1016/S0753-3322(00)80062-1. Biomed Pharmacother. 2000. PMID: 10989972
-
Large needle aspiration biopsy results of palpable thyroid nodules diagnosed by fine-needle aspiration as a microfollicular nodule with atypical cells or suspected cancer.Biomed Pharmacother. 2004 Jul-Aug;58(6-7):351-5. doi: 10.1016/j.biopha.2004.05.003. Biomed Pharmacother. 2004. PMID: 15271415
-
Thyroid fine needle aspiration: how to improve clinicians' confidence and performance with the technique.Cancer Lett. 2008 Jun 18;264(2):163-71. doi: 10.1016/j.canlet.2008.02.056. Epub 2008 Apr 1. Cancer Lett. 2008. PMID: 18384937 Review.
-
From the bench to the bedside. Galectin-3 immunodetection for improving the preoperative diagnosis of the follicular thyroid nodules.Biomed Pharmacother. 2004 Jul-Aug;58(6-7):356-9. doi: 10.1016/j.biopha.2004.05.004. Biomed Pharmacother. 2004. PMID: 15271416 Review.
Cited by
-
Testicular Fine-Needle Aspiration for Sperm Retrieval in Azoospermia: A Small Step toward the Technical Standardization.World J Mens Health. 2019 Jan;37(1):55-67. doi: 10.5534/wjmh.180077. World J Mens Health. 2019. PMID: 30584991 Free PMC article.
-
Are risk factors common to thyroid cancer and nodule? A forty years observational time-trend study.PLoS One. 2012;7(10):e47758. doi: 10.1371/journal.pone.0047758. Epub 2012 Oct 31. PLoS One. 2012. PMID: 23118895 Free PMC article.
-
Does large needle aspiration biopsy add pain to the thyroid nodule evaluation?PLoS One. 2013;8(3):e58016. doi: 10.1371/journal.pone.0058016. Epub 2013 Mar 11. PLoS One. 2013. PMID: 23536779 Free PMC article.
-
Diagnostic utility of galectin-3 in thyroid cancer.Am J Pathol. 2010 May;176(5):2067-81. doi: 10.2353/ajpath.2010.090353. Epub 2010 Apr 2. Am J Pathol. 2010. PMID: 20363921 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources