Genetic diversity of Legionella pneumophila in hospital water systems
- PMID: 17652025
- DOI: 10.1016/j.ijheh.2007.04.003
Genetic diversity of Legionella pneumophila in hospital water systems
Abstract
It has been shown that different patients who had acquired legionellosis in a hospital setting were infected with the same strain even years apart. However, there are no longitudinal data describing the molecular epidemiology of Legionella pneumophila strains that contaminate a water system. This raised the question if there are any shifts of L. pneumophila strains over time, or after carrying out control measures. Using genotyping on a large collection of isolates, we investigated in a retrospective study the distribution of L. pneumophila serogroups and PFGE types in six different hospitals of the University of Heidelberg between 1991 and 2001. A total of 2012 water samples were drawn for routine testing and for evaluation of control measures, 747 samples were positive for L. pneumophila. Serogroups were determined by latex agglutination or by direct fluorescence assay; and 515 L. pneumophila isolates from water systems and six from patients underwent PFGE typing after SfiI-restriction. We identified seven serogroups and 19 genotypes among the water isolates. Each hospital had one to four predominating PFGE types that were stable over the investigation period. The oldest buildings in hospitals 4 and 5 (built 1876 and 1907) had more types than the newest one (built 1986). In all hospitals PFGE types were identified that could be found only sporadically. Although each hospital had its own warm water supply, we identified types that could be found in more than one hospital. However, there was no overlap of types in buildings that were fed from different wells. Infrequently occurring nosocomial legionellosis (n=3) were only caused by predominant strains. Contamination of water supplies seemed to be dominated by stable genotypes, even after various control measures. Additional genotypes could be isolated sporadically, however, their pathogenetic relevance seemed to be questionable.
Similar articles
-
Clinical and environmental distribution of Legionella pneumophila in a university hospital in Italy: efficacy of ultraviolet disinfection.J Hosp Infect. 2006 Apr;62(4):494-501. doi: 10.1016/j.jhin.2005.09.029. Epub 2006 Feb 7. J Hosp Infect. 2006. PMID: 16455159
-
Detecting legionellosis by unselected culture of respiratory tract secretions and developing links to hospital water strains.J Hosp Infect. 1999 Apr;41(4):301-11. doi: 10.1053/jhin.1998.0517. J Hosp Infect. 1999. PMID: 10392336
-
Persistent Legionella pneumophila colonization of a hospital water supply: efficacy of control methods and a molecular epidemiological analysis.APMIS. 2005 Jan;113(1):45-53. doi: 10.1111/j.1600-0463.2005.apm1130107.x. APMIS. 2005. PMID: 15676014
-
Legionella pneumophila: population genetics, phylogeny and genomics.Infect Genet Evol. 2009 Sep;9(5):727-39. doi: 10.1016/j.meegid.2009.05.004. Epub 2009 May 18. Infect Genet Evol. 2009. PMID: 19450709 Review.
-
[Legionellosis--a new infection in Poland].Przegl Epidemiol. 2002;56(4):567-76. Przegl Epidemiol. 2002. PMID: 12666582 Review. Polish.
Cited by
-
Tap water as the source of a Legionnaires' disease outbreak spread to several residential buildings and one hospital, Finland, 2020 to 2021.Euro Surveill. 2023 Mar;28(11):2200673. doi: 10.2807/1560-7917.ES.2023.28.11.2200673. Euro Surveill. 2023. PMID: 36927717 Free PMC article.
-
Multiple Sources of the Outbreak of Legionnaires' Disease in Genesee County, Michigan, in 2014 and 2015.Environ Health Perspect. 2019 Dec;127(12):127001. doi: 10.1289/EHP5663. Epub 2019 Dec 4. Environ Health Perspect. 2019. PMID: 31799878 Free PMC article.
-
Longitudinal evaluation of the efficacy of heat treatment procedures against Legionella spp. in hospital water systems by using a flow cytometric assay.Appl Environ Microbiol. 2011 Feb;77(4):1268-75. doi: 10.1128/AEM.02225-10. Epub 2010 Dec 23. Appl Environ Microbiol. 2011. PMID: 21183641 Free PMC article.
-
Differential Bacterial Predation by Free-Living Amoebae May Result in Blooms of Legionella in Drinking Water Systems.Microorganisms. 2021 Jan 15;9(1):174. doi: 10.3390/microorganisms9010174. Microorganisms. 2021. PMID: 33467483 Free PMC article.
-
Effects of disinfection on Legionella spp., eukarya, and biofilms in a hot water system.Appl Environ Microbiol. 2012 Oct;78(19):6850-8. doi: 10.1128/AEM.00831-12. Epub 2012 Jul 20. Appl Environ Microbiol. 2012. PMID: 22820326 Free PMC article.