Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2007 Jul 26;357(4):349-59.
doi: 10.1056/NEJMoa063232.

Partial thrombosis of the false lumen in patients with acute type B aortic dissection

Affiliations
Free article

Partial thrombosis of the false lumen in patients with acute type B aortic dissection

Thomas T Tsai et al. N Engl J Med. .
Free article

Abstract

Background: Patency or thrombosis of the false lumen in type B acute aortic dissection has been found to predict outcomes. The prognostic implications of partial thrombosis of the false lumen have not yet been elucidated.

Methods: We examined 201 patients with type B acute aortic dissection who were enrolled in the International Registry of Acute Aortic Dissection between 1996 and 2003 and who survived to hospital discharge. Kaplan-Meier mortality curves were stratified according to the status of the false lumen (patent, partial thrombosis, or complete thrombosis) as determined during the index hospitalization. Cox proportional-hazards analysis was performed to identify independent predictors of death.

Results: During the index hospitalization, 114 patients (56.7%) had a patent false lumen, 68 patients (33.8%) had partial thrombosis of the false lumen, and 19 (9.5%) had complete thrombosis of the false lumen. The mean (+/-SD) 3-year mortality rate for patients with a patent false lumen was 13.7+/-7.1%, for those with partial thrombosis was 31.6+/-12.4%, and for those with complete thrombosis was 22.6+/-22.6% (median follow-up, 2.8 years; P=0.003 by the log-rank test). Independent predictors of postdischarge mortality were partial thrombosis of the false lumen (relative risk, 2.69; 95% confidence interval [CI], 1.45 to 4.98; P=0.002), a history of aortic aneurysm (relative risk, 2.05; 95% CI, 1.07 to 3.93; P=0.03), and a history of atherosclerosis (relative risk, 1.87; 95% CI, 1.01 to 3.47; P=0.05).

Conclusions: Mortality is high after discharge from the hospital among patients with type B acute aortic dissection. Partial thrombosis of the false lumen, as compared with complete patency, is a significant independent predictor of postdischarge mortality in these patients.

PubMed Disclaimer

Comment in

Publication types

LinkOut - more resources