Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2007 Jun;9(3):305-9.

The effect of saliva contamination on microleakage of an etch-and-rinse and a self-etching adhesive

Affiliations
  • PMID: 17655070
Comparative Study

The effect of saliva contamination on microleakage of an etch-and-rinse and a self-etching adhesive

A Rüya Yazici et al. J Adhes Dent. 2007 Jun.

Abstract

Purpose: To evaluate the effect of saliva contamination on the microleakage of an etch-and-rinse adhesive and a self-etching adhesive.

Materials and methods: Class V cavity preparations at the cementoenamel junction were made on the buccal and lingual surfaces of 40 freshly extracted human molars. The teeth were randomly assigned into two groups for different adhesives: Group I, Single Bond (two-step etch-and-rinse adhesive) and Group II, Futura Bond NR (one-step self-etching adhesive). The adhesive materials were applied according to their manufacturers' recommendations. The specimens were then further subdivided into five subgroups (A-E; n = 8): group A, contamination before adhesive curing; group B, contamination before adhesive curing and re-application of adhesive; group C, contamination after adhesive curing; group D, contamination after adhesive curing and re-application of adhesive; and group E, no contamination (control). Contamination of adhesive surfaces was performed with fresh natural saliva and the saliva was removed by a gentle air blast. The specimens were restored with Z250 hybrid composite. After thermocycling (500x, 5 degrees C to 55 degrees C) and immersion in 0.5% basic fuchsin, the dye penetration was evaluated under a stereomicroscope. Statistical analysis was performed with the Kruskal-Wallis test at p < 0.05.

Results: No statistically significant differences were found among the contamination subgroups on the enamel or on the dentin for either group (p > 0.05). There was no significant difference in leakage between Group I and Group II for any subgroup (p > 0.05).

Conclusion: Contamination of adhesives with saliva before and after adhesive curing did not worsen the microleakage of the two-step etch-and-rinse adhesive Single Bond or the one-step self-etching adhesive Futura Bond NR.