Bacterial contamination of water in dental unit reservoirs
- PMID: 17655191
Bacterial contamination of water in dental unit reservoirs
Abstract
The aim of this study was bacteriological assessment of water in dental unit reservoirs--concentration and composition of the aerobe and facultative anaerobe bacterial microflora. Reservoir water samples were taken from 25 units. Bacterial flora were determined with the plate culture method. Bacteria were identified with biochemical microtests: API 20E, API 20NE (bioMérieux, France) and GP2 MicroPlateTM (BIOLOG, USA). The concentration of total bacteria isolated from one site was 201,039 cfu/ml, on average; the minimum was 22,300 cfu/ml, and the maximum - 583,000 cfu/ml. The following bacteria were identified: Gram-negative bacteria--Brevundimonas vesicularis, Moraxella lacunata, Moraxella spp., Ralstonia pickettii, Sphingomonas paucimobilis, Stenotrophomonas maltophilia; Gram-positive cocci--Micrococcus luteus, Micrococcus lylae, Staphylococcus cohnii, Staphylococcus hominis ss novobiosepticus, Staphylococcus spp., Streptococcus spp.; actinomycetes--Streptomyces albus. The prevailing bacteria were: Ralstonia pickettii (96.46%), found in all the units. Sphingomonas paucimobilis (1.32%) and Brevundimonas vesicularis (1.07%) were the next most frequently occurring bacteria. Bacteria concentration in dental unit reservoirs reached excessive values, and the bacterial flora were composed of the bacteria characteristic for water supply systems, opportunistic pathogens, and bacteria of the oral cavity flora. Continuous microbiological monitoring of the DUWL water, including application of a disinfecting procedure, is necessary.
Similar articles
-
Bacterial decontamination of DUWL biofilm using Oxygenal 6.Ann Agric Environ Med. 2006;13(1):163-7. Ann Agric Environ Med. 2006. PMID: 16841887
-
A novel automated waterline cleaning system that facilitates effective and consistent control of microbial biofilm contamination of dental chair unit waterlines: a one-year study.J Dent. 2006 Oct;34(9):648-61. doi: 10.1016/j.jdent.2005.12.006. Epub 2006 Jan 24. J Dent. 2006. PMID: 16442201
-
Antifungal efficacy of hydrogen peroxide in dental unit waterline disinfection.Ann Agric Environ Med. 2006;13(2):313-7. Ann Agric Environ Med. 2006. PMID: 17196007
-
Dental unit water contamination.J Can Dent Assoc. 1996 Jun;62(6):492-5. J Can Dent Assoc. 1996. PMID: 8752646 Review.
-
Microbial biofilm formation in DUWS and their control using disinfectants.J Dent. 2007 Sep;35(9):721-30. doi: 10.1016/j.jdent.2007.07.005. Epub 2007 Aug 21. J Dent. 2007. PMID: 17714847 Review.
Cited by
-
A comparison of 2 laboratory methods to test dental unit waterline water quality.Diagn Microbiol Infect Dis. 2013 Nov;77(3):206-8. doi: 10.1016/j.diagmicrobio.2013.07.010. Epub 2013 Sep 17. Diagn Microbiol Infect Dis. 2013. PMID: 24054735 Free PMC article.
-
A survey of the bacterial diversity in the cup filler of dental chair units.Braz J Microbiol. 2011 Jul;42(3):959-63. doi: 10.1590/S1517-838220110003000015. Epub 2011 Sep 1. Braz J Microbiol. 2011. PMID: 24031712 Free PMC article.
-
Evaluation of 3 dental unit waterline contamination testing methods.Gen Dent. 2015 Jan-Feb;63(1):41-7. Gen Dent. 2015. PMID: 25574718 Free PMC article.
-
Comparative evaluation of effect of sodium hypochlorite and chlorhexidine in dental unit waterline on aerosolized bacteria generated during dental treatment.BMC Oral Health. 2023 Nov 14;23(1):865. doi: 10.1186/s12903-023-03585-9. BMC Oral Health. 2023. PMID: 37964280 Free PMC article.
-
Biofilms on Hospital Shower Hoses: Characterization and Implications for Nosocomial Infections.Appl Environ Microbiol. 2016 Apr 18;82(9):2872-2883. doi: 10.1128/AEM.03529-15. Print 2016 May. Appl Environ Microbiol. 2016. PMID: 26969701 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Miscellaneous