Determination of sugar phosphates by high-performance anion-exchange chromatography coupled with pulsed amperometric detection
- PMID: 17658539
- DOI: 10.1016/j.chroma.2007.07.007
Determination of sugar phosphates by high-performance anion-exchange chromatography coupled with pulsed amperometric detection
Abstract
We have developed an improved analytical method for the determination of sugar phosphates using sodium carbonate (Na(2)CO(3)) for high-performance anion-exchange chromatography-pulsed amperometric detection. The target analytes were separated completely within 10 min using eluent containing 20 mM NaOH and 35 mM Na(2)CO(3). The limit of detection (S/N=3) and quantitation (S/N=10) for analytes were 10-30 ng/mL and 35-100 ng/mL, respectively. Linear dynamic range was 1-30 microg/mL (r(2)> or =0.9998). The RSDs for intra- and inter-day assays were found to be of satisfactory results (0.23-3.09%), and the recoveries from blood spots were 97.62-99.69%.
Similar articles
-
Development of a new diagnostic method for galactosemia by high-performance anion-exchange chromatography with pulsed amperometric detection.J Chromatogr A. 2007 Jan 26;1140(1-2):157-62. doi: 10.1016/j.chroma.2006.11.085. Epub 2006 Dec 11. J Chromatogr A. 2007. PMID: 17161845
-
Determination of phenylalanine in blood by high-performance anion-exchange chromatography-pulsed amperometric detection to diagnose phenylketonuria.J Chromatogr A. 2009 Jul 24;1216(30):5709-14. doi: 10.1016/j.chroma.2009.06.004. Epub 2009 Jun 7. J Chromatogr A. 2009. PMID: 19540504
-
A pulsed amperometric detection method of galactose 1-phosphate for galactosemia diagnosis.Anal Biochem. 2008 May 15;376(2):200-5. doi: 10.1016/j.ab.2008.02.024. Epub 2008 Feb 29. Anal Biochem. 2008. PMID: 18358226
-
Analyzing sialic acids using high-performance anion-exchange chromatography with pulsed amperometric detection.Anal Biochem. 2000 Jul 15;283(1):3-9. doi: 10.1006/abio.2000.4643. Anal Biochem. 2000. PMID: 10929801 Review. No abstract available.
-
Analysis of amino acid-carbohydrate mixtures by anion exchange chromatography and integrated pulsed amperometric detection.J Biochem Biophys Methods. 2004 Sep 30;60(3):191-203. doi: 10.1016/j.jbbm.2004.01.003. J Biochem Biophys Methods. 2004. PMID: 15345292 Review.
Cited by
-
Analysis of selected sugars and sugar phosphates in mouse heart tissue by reductive amination and liquid chromatography-electrospray ionization mass spectrometry.Anal Chem. 2013 Jun 18;85(12):5965-73. doi: 10.1021/ac400769g. Epub 2013 May 30. Anal Chem. 2013. PMID: 23682691 Free PMC article.
-
A simple and rapid method for measuring α-D-phosphohexomutases activity by using anion-exchange chromatography coupled with an electrochemical detector.PeerJ. 2016 Jan 5;4:e1517. doi: 10.7717/peerj.1517. eCollection 2016. PeerJ. 2016. PMID: 26788420 Free PMC article.
-
Transcriptome analysis suggests that starch synthesis may proceed via multiple metabolic routes in high yielding potato cultivars.PLoS One. 2012;7(12):e51248. doi: 10.1371/journal.pone.0051248. Epub 2012 Dec 17. PLoS One. 2012. PMID: 23284672 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources