Multi-frequency parameter mapping of electrical impedance scanning using two kinds of circuit model
- PMID: 17664650
- DOI: 10.1088/0967-3334/28/7/S07
Multi-frequency parameter mapping of electrical impedance scanning using two kinds of circuit model
Abstract
Electrical impedance scanning (EIS) is a kind of potential bio-impedance measurement technology, especially aiding the diagnosis of breast cancer in women. By changing the frequency of the driving signal in turn while keeping the other conditions stable, multi-frequency measurement results on the object can be obtained. According to the least square method and circuit theory, the parameters in two models are deduced when measured with data at multiple driving frequencies. The arcs, in the real and imaginary parts of a trans-admittance coordinate, made by the evaluated parameters fit well the realistic data measured by our EIS device on female subjects. The Cole-Cole model in the form of admittance is closer to the measured data than the three-element model. Based on the evaluation of the multi-frequency parameters, we presented parameter mapping of EIS using two kinds of circuit model: one is the three-element model in the form of admittance and the other is the Cole-Cole model in the form of admittance. Comparing with classical admittance mapping at a single frequency, the multi-frequency parameter mapping will provide a novel vision to study EIS. The multi-frequency approach can provide the mappings of four parameters, which is helpful to identify different diseases with a similar characteristic in classical EIS mapping. From plots of the real and imaginary parts of the admittance, it is easy to make sure whether there exists abnormal tissue.
Similar articles
-
Feasibility of breast cancer lesion detection using a multi-frequency trans-admittance scanner (TAS) with 10 Hz to 500 kHz bandwidth.Physiol Meas. 2007 Jul;28(7):S71-84. doi: 10.1088/0967-3334/28/7/S06. Epub 2007 Jun 26. Physiol Meas. 2007. PMID: 17664649
-
[Frequency characteristic of diseased breast tissues detected by electrical impedance scanning].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2005 Dec;22(6):1090-4. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2005. PMID: 16422073 Chinese.
-
Towards virtual electrical breast biopsy: space-frequency MUSIC for trans-admittance data.IEEE Trans Med Imaging. 2002 Jun;21(6):588-95. doi: 10.1109/TMI.2002.800609. IEEE Trans Med Imaging. 2002. PMID: 12166854
-
Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods.Med Eng Phys. 2008 Dec;30(10):1257-69. doi: 10.1016/j.medengphy.2008.06.009. Epub 2008 Aug 3. Med Eng Phys. 2008. PMID: 18676172 Review.
-
[Electrical impedance tomography technology].Zhongguo Yi Liao Qi Xie Za Zhi. 1999 Nov;23(6):340-3. Zhongguo Yi Liao Qi Xie Za Zhi. 1999. PMID: 12583086 Review. Chinese. No abstract available.
Cited by
-
Cancer Detection Based on Electrical Impedance Spectroscopy: A Clinical Study.J Electr Bioimpedance. 2018 Aug 16;9(1):17-23. doi: 10.2478/joeb-2018-0004. eCollection 2018 Jan. J Electr Bioimpedance. 2018. PMID: 33584916 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical