The innominate vein as alternative venous access for complicated implantable cardioverter defibrillator revisions
- PMID: 17669077
- DOI: 10.1111/j.1540-8159.2007.00792.x
The innominate vein as alternative venous access for complicated implantable cardioverter defibrillator revisions
Abstract
Background: Venous complications of implantable cardioverter defibrillator (ICD) systems may cause significant problems when the need for system revision or upgrades arises. Such revisions require venous access close to the site of the previous ICD implantation. The internal and external jugular vein have disadvantages due to a long subcutaneous course crossing the clavicle and problems with lead extraction if infection occurs.
Methods: In seven patients with ICD revisions due to lead dysfunction (n = 4) and upgrade to a biventricular device (n = 2) and status after system removal due to infection with new device implantation (n = 1) conventional venous access could not be obtained. Intraoperative contrast venography demonstrated an occluded left subclavian and/or left innominate vein in all patients. In all patients, we gained venous access through puncture of the right innominate vein and tunneled the new lead subcutaneously to the ICD pocket on the left.
Results: No intraoperative complications were observed. All patients are followed in our ICD clinic. Mean follow-up is 16 +/- 4 months now. So far, no clinical or lead complications with this access have been observed.
Conclusions: We have demonstrated that ICD lead placement through puncture of the right innominate vein is feasible. We propose the innominate vein as an alternative route for establishing venous access in patients requiring ICD revisions or upgrades who suffer from venous obstruction. ICD implanting physicians should acquaint themselves with the technique of right innominate vein puncture to use this vein as a bail-out strategy in patients with complicated venous access.
Similar articles
-
Nontraditional surgical approaches for implantation of pacemaker and cardioverter defibrillator systems in patients with limited venous access.Ann Thorac Surg. 2009 Jul;88(1):112-6. doi: 10.1016/j.athoracsur.2009.04.006. Ann Thorac Surg. 2009. PMID: 19559206
-
Nontraditional implantable cardioverter defibrillator placement in adult patients with limited venous access: a case series.Pacing Clin Electrophysiol. 2010 Feb;33(2):217-25. doi: 10.1111/j.1540-8159.2009.02577.x. Epub 2009 Oct 5. Pacing Clin Electrophysiol. 2010. PMID: 19804488
-
Predictors of venous obstruction following pacemaker or implantable cardioverter-defibrillator implantation: a contrast venographic study on 100 patients admitted for generator change, lead revision, or device upgrade.Europace. 2007 May;9(5):328-32. doi: 10.1093/europace/eum019. Epub 2007 Mar 16. Europace. 2007. PMID: 17369270
-
Venous thrombosis and stenosis after implantation of pacemakers and defibrillators.J Interv Card Electrophysiol. 2005 Jun;13(1):9-19. doi: 10.1007/s10840-005-1140-1. J Interv Card Electrophysiol. 2005. PMID: 15976973 Review.
-
Extraction of transvenous pacing and ICD leads.Pacing Clin Electrophysiol. 2008 Jun;31(6):736-52. doi: 10.1111/j.1540-8159.2008.01079.x. Pacing Clin Electrophysiol. 2008. PMID: 18507548 Review.
Cited by
-
Contralateral transvenous left ventricular lead placement of implantable devices with pre-sternal tunnelling in chronically obstructed subclavian veins.Indian Pacing Electrophysiol J. 2015 Jul 29;15(2):113-7. doi: 10.1016/j.ipej.2015.07.007. eCollection 2015 Mar-Apr. Indian Pacing Electrophysiol J. 2015. PMID: 26937096 Free PMC article.
-
Contralateral transvenous left ventricular lead placement of an implantable device with pre-sternal tunneling in an ipsilateral chronically obstructed subclavian vein.Clin Case Rep. 2024 Aug 10;12(8):e9321. doi: 10.1002/ccr3.9321. eCollection 2024 Aug. Clin Case Rep. 2024. PMID: 39130806 Free PMC article.
-
Venous Obstruction in Cardiac Rhythm Device Therapy.Curr Treat Options Cardiovasc Med. 2018 Jul 11;20(8):64. doi: 10.1007/s11936-018-0664-5. Curr Treat Options Cardiovasc Med. 2018. PMID: 29995225 Review.
-
Placement Of A Coronary Sinus Pacing Lead From A Sub-occluded Left Subclavian Vein Using A Collateral Vein To The Right Subclavian Vein.Indian Pacing Electrophysiol J. 2011 Nov;11(6):176-9. Epub 2011 Nov 15. Indian Pacing Electrophysiol J. 2011. PMID: 22090732 Free PMC article.
-
Overcoming a subclavian complete occlusion: Simple single lead extraction by the subclavian vein allowing implantation of two new leads and upgrade to CRT-P with multi-site pacing.Indian Pacing Electrophysiol J. 2015 Jul 29;15(2):118-20. doi: 10.1016/j.ipej.2015.07.008. eCollection 2015 Mar-Apr. Indian Pacing Electrophysiol J. 2015. PMID: 26937097 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical