Comparative Study
. 2007 Jun;5(2):267-82.

A comparison of ten USEPA approved total coliform/E. coli tests

Affiliations
  • PMID: 17674575
Comparative Study

A comparison of ten USEPA approved total coliform/E. coli tests

Jeremy Olstadt et al. J Water Health. 2007 Jun.

Abstract

Since 2002, the United States Environmental Protection Agency (USEPA) has approved ten enzyme-based total coliform and E. coli detection tests for examination of drinking water. These tests include: Colilert, Colilert-18, Colisure, m-Coli Blue 24, Readycult Coliforms 100, Chromocult, Coliscan, E * Colite, Colitag and MI Agar. The utility of the enzyme based test systems is based on both the ability of the test to detect the target organisms at low levels and the ability of the test system to suppress the growth of non-target organisms that might result in false positive results. Differences in the ability of some of these methods to detect total coliform and E. coli, as well as suppress Aeromonas spp., a common cause of "false positive" results, have been observed. As a result, this study was undertaken to elucidate the strengths and weaknesses of each method. Water samples were collected from three geographically and chemically diverse groundwaters in Wisconsin. One-hundred milliliter aliquots were individually spiked with both low concentrations (one to ten organisms) and high concentrations (fifty to one-hundred) of each of five different total coliform organisms (Serratia, Citrobacter, Enterobacter, E. coli, & Klebsiella). These spiked samples were used to test the capability of ten enzyme-based test systems to both detect and enumerate the spiked organisms. In addition, 100 ml samples were independently spiked with two different strains of Aeromonas spp. at six different levels, to assess the ability of each enzyme-based test to suppress Aeromonas spp. Analysis of the data indicated that wide variability exists among USEPA approved tests to detect and quantify total coliforms, as well as suppress Aeromonas spp.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources