Use of a disposable water filter for prevention of false-positive results due to nontuberculosis mycobacteria in a clinical laboratory performing routine acid-fast staining for tuberculosis
- PMID: 17675421
- PMCID: PMC2074995
- DOI: 10.1128/AEM.00325-07
Use of a disposable water filter for prevention of false-positive results due to nontuberculosis mycobacteria in a clinical laboratory performing routine acid-fast staining for tuberculosis
Abstract
A point-of-use 0.2-microm filter was evaluated for elimination of nontuberculosis mycobacteria in laboratory water to reduce false-positive acid-fast bacillus staining results. Use of the point-of-use filter can significantly reduce the false-positive rate to 1.2% compared to samples treated with tap water (10.7%) and deionized water (8.7%).
Figures
Similar articles
-
Use of terminal tap water filter systems for prevention of nosocomial legionellosis.J Hosp Infect. 2005 Jun;60(2):159-62. doi: 10.1016/j.jhin.2004.10.018. J Hosp Infect. 2005. PMID: 15866015
-
Impact of a silver layer on the membrane of tap water filters on the microbiological quality of filtered water.BMC Infect Dis. 2008 Oct 8;8:133. doi: 10.1186/1471-2334-8-133. BMC Infect Dis. 2008. PMID: 18842119 Free PMC article.
-
[Mycobacterial tests].Kekkaku. 2008 Jan;83(1):43-59. Kekkaku. 2008. PMID: 18283915 Japanese.
-
Review of false-positive cultures for Mycobacterium tuberculosis and recommendations for avoiding unnecessary treatment.Clin Infect Dis. 2000 Dec;31(6):1390-5. doi: 10.1086/317504. Epub 2000 Nov 17. Clin Infect Dis. 2000. PMID: 11096008 Review.
-
[Modern laboratory diagnostics for mycobacteria].Pneumologie. 2008 Sep;62(9):533-40. doi: 10.1055/s-2008-1038242. Epub 2008 Sep 3. Pneumologie. 2008. PMID: 18770479 Review. German.
Cited by
-
An Update on Global Tuberculosis (TB).Infect Dis (Auckl). 2013 May 21;6:39-50. doi: 10.4137/IDRT.S11263. eCollection 2013. Infect Dis (Auckl). 2013. PMID: 24847176 Free PMC article. Review.
-
Physical Measures to Reduce Exposure to Tap Water-Associated Nontuberculous Mycobacteria.Front Public Health. 2020 Jun 12;8:190. doi: 10.3389/fpubh.2020.00190. eCollection 2020. Front Public Health. 2020. PMID: 32596197 Free PMC article.
References
-
- du Moulin, G. C., K. D. Stottmeier, P. A. Pelletier, A. Y. Tsang, and J. Hedley-Whyte. 1988. Concentration of Mycobacterium avium by hospital hot water systems. JAMA 260:1599-1601. - PubMed
-
- Glover, N., A. Holtzman, T. Aronson, S. Froman, O. G. Berlin, P. Dominguez, K. A. Kunkel, G. Overturf, G. N. Stelma, C. Smith, and M. Yakrus. 1994. The isolation and identification of Mycobacterium avium complex (MAC) recovered from Los Angeles potable water, a possible source of infection in AIDS patients. Int. J. Environ. Health Res. 4:63-72.
-
- Gonzalez, J., G. Tudo, J. Gomez, A. Garcia, M. Navarro, and M. T. Jimenez de Anta. 1998. Use of microscopic morphology in smears prepared from radiometric cultures for presumptive identification of Mycobacterium tuberculosis complex, Mycobacterium avium complex, Mycobacterium kansasii, and Mycobacterium xenopi. Eur. J. Clin. Microbiol. Infect. Dis. 17:493-500. - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous