Noninvasive pulse waveform analysis in clinical trials: similarity of two methods for calculating aortic systolic pressure
- PMID: 17679043
- DOI: 10.1016/j.amjhyper.2007.03.006
Noninvasive pulse waveform analysis in clinical trials: similarity of two methods for calculating aortic systolic pressure
Abstract
Background: Concerns persist about the validity of generalized transfer function-derived, aortic blood-pressure measurements during the administration of vasoactive agents in clinical trials. Hence, we compared this transfer-function method with another, which estimates aortic systolic pressure directly from the late systolic shoulder of the radial pressure wave, after administration of placebo, ramipril, or atenolol.
Methods: We recorded radial pressure pulse waveforms, using a commercially available system, in 30 subjects with >or=1 coronary risk factor in an acute study of ramipril at 10 mg and atenolol at 100 mg. Directly recorded radial and derived aortic pressure pulse waveforms were examined individually and were ensemble-averaged, and the difference between radial and aortic pressure responses was examined.
Results: The late systolic shoulder response from radial waveforms was reduced by 15.8 mm Hg (SD, 12.2 mm Hg) more with ramipril than with atenolol. This was similar to a difference of 14.6 mm Hg (SD, 11.2 mm Hg) calculated for the aortic systolic pressure response using the transfer-function technique. Ramipril caused a greater reduction in the aortic systolic pressure response (22.2 mm Hg), whereas with atenolol, there was a modest decrease (7.6 mm Hg). The mean difference between aortic systolic pressures measured from direct radial waveforms and from derived aortic pressure between 3 and 5 h after dosing under all circumstances was 1.6 mm Hg (SD, 8.9 mm Hg).
Conclusions: Central pressure derived from radial pressure waveforms using a generalized transfer function gave similar results for central pressure measured directly from radial waveforms. The hemodynamic benefits of angiotensin-converting enzyme inhibitor, angiotensin receptor blocker, and calcium channel blocker over beta-blocker antihypertensive therapy in recent trials were confirmed by this study.
Similar articles
-
Effect of non-invasive calibration of radial waveforms on error in transfer-function-derived central aortic waveform characteristics.Clin Sci (Lond). 2004 Aug;107(2):205-11. doi: 10.1042/CS20030294. Clin Sci (Lond). 2004. PMID: 15139848
-
Cuff and aortic pressure differences during dobutamine infusion: a study of the effects of systolic blood pressure amplification.Am Heart J. 2010 Mar;159(3):399-405. doi: 10.1016/j.ahj.2009.12.010. Am Heart J. 2010. PMID: 20211301
-
Transmission of calibration errors (input) by generalized transfer functions to the aortic pressures (output) at different hemodynamic states.Int J Cardiol. 2006 Jun 7;110(1):46-52. doi: 10.1016/j.ijcard.2005.07.014. Epub 2005 Oct 17. Int J Cardiol. 2006. PMID: 16229910
-
Clinical measurement of arterial stiffness obtained from noninvasive pressure waveforms.Am J Hypertens. 2005 Jan;18(1 Pt 2):3S-10S. doi: 10.1016/j.amjhyper.2004.10.009. Am J Hypertens. 2005. PMID: 15683725 Review.
-
Validation of the transfer function technique for generating central from peripheral upper limb pressure waveform.Am J Hypertens. 2004 Nov;17(11 Pt 1):1059-67. doi: 10.1016/j.amjhyper.2004.05.027. Am J Hypertens. 2004. PMID: 15533735 Review.
Cited by
-
Increased wave reflection and ejection duration in women with chest pain and nonobstructive coronary artery disease: ancillary study from the Women's Ischemia Syndrome Evaluation.J Hypertens. 2013 Jul;31(7):1447-54; discussion 1454-5. doi: 10.1097/HJH.0b013e3283611bac. J Hypertens. 2013. PMID: 23615325 Free PMC article.
-
Reference values for the augmentation index and pulse pressure in apparently healthy korean subjects.Korean Circ J. 2010 Apr;40(4):165-71. doi: 10.4070/kcj.2010.40.4.165. Epub 2010 Apr 22. Korean Circ J. 2010. PMID: 20421956 Free PMC article.
-
Patient-specific pulse wave propagation model identifies cardiovascular risk characteristics in hemodialysis patients.PLoS Comput Biol. 2018 Sep 14;14(9):e1006417. doi: 10.1371/journal.pcbi.1006417. eCollection 2018 Sep. PLoS Comput Biol. 2018. PMID: 30216341 Free PMC article.
-
Noninvasive measurement of central vascular pressures with arterial tonometry: clinical revival of the pulse pressure waveform?Mayo Clin Proc. 2010 May;85(5):460-72. doi: 10.4065/mcp.2009.0336. Mayo Clin Proc. 2010. PMID: 20435839 Free PMC article. Review.
-
Atenolol's Inferior Ability to Reduce Central vs Peripheral Blood Pressure Can Be Explained by the Combination of Its Heart Rate-Dependent and Heart Rate-Independent Effects.Int J Hypertens. 2020 Apr 26;2020:4259187. doi: 10.1155/2020/4259187. eCollection 2020. Int J Hypertens. 2020. PMID: 32395337 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical