Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 1991 Nov;11(6):565-77.
doi: 10.1111/j.1475-097x.1991.tb00676.x.

Ultrasound measurement of wall thickness in the carotid artery: fundamental principles and description of a computerized analysing system

Affiliations
Review

Ultrasound measurement of wall thickness in the carotid artery: fundamental principles and description of a computerized analysing system

I Wendelhag et al. Clin Physiol. 1991 Nov.

Abstract

A B-mode [two-dimensional (2D)] image from the carotid artery may be described as containing seven echo zones. The aim of the present work is to discuss how lumen diameter and wall thickness can be measured from these zones, and to review some of the basic principles of ultrasound physics and imaging. Simple experiments were performed to identify the echoes defining intima-lumen interfaces. The results showed that: (1) The intima-media thickness of the near wall cannot be measured in a valid way. (2) The lumen diameter of a blood vessel is defined by the distance from the leading edge of the intima-lumen interface of the near wall (echo zone 3) to the leading edge of the lumen-intima interface of the fall wall (echo zone 5). (3) Previously published studies have validated the intima-media complex of the far wall as the distance from the leading edge of the lumen-intima interface of the far wall to the leading edge of the media-adventitia interface of the far wall (echo zone 7). We suggest that if measurements on the near wall are performed, measurements from the far wall should also be presented separately, and if lumen diameter is measured, that this measurement is carried out according to the leading edge principle. We describe a computerized analysing system for the measurement of wall thickness and plaque area on the carotid and femoral arteries. The system is based on a low-cost PC and a frame grabber board and calculates minimum, maximum and mean values of lumen diameter and wall thickness from a section of the artery.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources