The protocols and codes of practice used for the determination of absorbed dose in megavoltage photon and electron beams
- PMID: 1769240
The protocols and codes of practice used for the determination of absorbed dose in megavoltage photon and electron beams
Abstract
Air kerma-to-dose and exposure-to-dose conversion factors for megavoltage photon beams and electron beams are derived for a variety of commonly used ionization chambers, using the various dosimetry protocols and codes of practice currently in use. It is found that differences in the resultant values are present for both photon and electron beams. For example, for a NE2571 graphite-walled thimble ionization chamber, the maximum variation in the air kerma-to-dose conversion factor for photons, Cw,lambda, occurs at a "nominal" energy of 25 MV, when the difference between the maximum and minimum value of Cw,lambda is 5.4%, whereas the maximum difference between different protocols in the air kerma-to-dose conversion factor for electrons, Cw,e, occurs at Eo = 9 MeV, when the spread between maximum and minimum Cw,e values is 2.7%. An analysis of the conversion factors is undertaken to examine if the numerical or theoretical data are the cause of the discrepancies, and it is found to be a combination of both, although the major contribution to this difference arises from the use of different sets of stopping power ratios in the different protocols.
Similar articles
-
Protocols for the dosimetry of high-energy photon and electron beams: a comparison of the IAEA TRS-398 and previous international codes of practice. International Atomic Energy Agency.Phys Med Biol. 2002 Sep 7;47(17):3033-53. doi: 10.1088/0031-9155/47/17/301. Phys Med Biol. 2002. PMID: 12361209
-
Calculated absorbed-dose ratios, TG51/TG21, for most widely used cylindrical and parallel-plate ion chambers over a range of photon and electron energies.Med Phys. 2002 Jul;29(7):1464-72. doi: 10.1118/1.1487857. Med Phys. 2002. PMID: 12148727
-
A comparison of protocols for external beam radiotherapy beam calibrations.Appl Radiat Isot. 2012 Jul;70(7):1331-6. doi: 10.1016/j.apradiso.2011.11.065. Epub 2012 Jan 25. Appl Radiat Isot. 2012. PMID: 22608983
-
Dosimetry of clinical neutron and proton beams: an overview of recommendations.Radiat Prot Dosimetry. 2004;110(1-4):565-72. doi: 10.1093/rpd/nch221. Radiat Prot Dosimetry. 2004. PMID: 15353710 Review.
-
Advances in the determination of absorbed dose to water in clinical high-energy photon and electron beams using ionization chambers.Phys Med Biol. 2004 Feb 21;49(4):R49-104. doi: 10.1088/0031-9155/49/4/r01. Phys Med Biol. 2004. PMID: 15005158 Review.