An automated system for 24-h monitoring of cough frequency: the leicester cough monitor
- PMID: 17694868
- DOI: 10.1109/TBME.2007.900811
An automated system for 24-h monitoring of cough frequency: the leicester cough monitor
Abstract
The objective monitoring of cough for extended periods of time has long been recognized as an important step towards a better understanding of this symptom, and a better management of chronic cough patients. In this paper, we present a system for the automatic analysis of 24-h, continuous, ambulatory recordings of cough. The system uses audio recordings from a miniature microphone and the detection algorithm is based on statistical models of the time-spectral characteristics of cough sounds. We validated the system against manual counts obtained by a trained observer on 40 ambulatory recordings and our results show a median sensitivity value of 85.7%, median positive predictive value of 94.7% and median false positive rate of 0.8 events/h. An analysis application was developed, with a graphical user interface, allowing the use of the system in clinical settings by technical or medical staff. The result of the analysis of a recording session is presented as a concise, graphical-based report. The modular nature of the system interface facilitates its enhancement with the integration of further modules.
Similar articles
-
Detection of cough signals in continuous audio recordings using hidden Markov models.IEEE Trans Biomed Eng. 2006 Jun;53(6):1078-83. doi: 10.1109/TBME.2006.873548. IEEE Trans Biomed Eng. 2006. PMID: 16761835 Clinical Trial.
-
Breathing detection: towards a miniaturized, wearable, battery-operated monitoring system.IEEE Trans Biomed Eng. 2008 Jan;55(1):196-204. doi: 10.1109/TBME.2007.910679. IEEE Trans Biomed Eng. 2008. PMID: 18232362
-
Mobile nocturnal long-term monitoring of wheezing and cough.Biomed Tech (Berl). 2007 Feb;52(1):73-6. doi: 10.1515/BMT.2007.014. Biomed Tech (Berl). 2007. PMID: 17313338
-
Technologies for developing ambulatory cough monitoring devices.Crit Rev Biomed Eng. 2013;41(6):457-68. Crit Rev Biomed Eng. 2013. PMID: 24940659 Review.
-
[Normal and Adventitious Breath Sounds].Pneumologie. 2016 Jun;70(6):397-404. doi: 10.1055/s-0042-106155. Epub 2016 May 13. Pneumologie. 2016. PMID: 27177168 Review. German.
Cited by
-
Cough reflex sensitivity improves with speech language pathology management of refractory chronic cough.Cough. 2010 Jul 28;6:5. doi: 10.1186/1745-9974-6-5. Cough. 2010. PMID: 20663225 Free PMC article.
-
Diagnosis and treatment of patients with nonacid gastroesophageal reflux-induced chronic cough.J Res Med Sci. 2015 Sep;20(9):885-92. doi: 10.4103/1735-1995.170625. J Res Med Sci. 2015. PMID: 26759577 Free PMC article. Review.
-
Protocol for studying cough frequency in people with pulmonary tuberculosis.BMJ Open. 2016 Apr 22;6(4):e010365. doi: 10.1136/bmjopen-2015-010365. BMJ Open. 2016. PMID: 27105713 Free PMC article.
-
Clinical Practice Guidelines for Diagnosis and Management of Cough-Chinese Thoracic Society (CTS) Asthma Consortium.J Thorac Dis. 2018 Nov;10(11):6314-6351. doi: 10.21037/jtd.2018.09.153. J Thorac Dis. 2018. PMID: 30622806 Free PMC article. Review. No abstract available.
-
Automated Cough Assessment on a Mobile Platform.J Med Eng. 2014;2014:951621. doi: 10.1155/2014/951621. J Med Eng. 2014. PMID: 25506590 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical