. 2007 Sep 15;79(18):7069-77.
doi: 10.1021/ac0707939. Epub 2007 Aug 14.

Non-proximate detection of small and large molecules by desorption electrospray ionization and desorption atmospheric pressure chemical ionization mass spectrometry: instrumentation and applications in forensics, chemistry, and biology

Affiliations

Non-proximate detection of small and large molecules by desorption electrospray ionization and desorption atmospheric pressure chemical ionization mass spectrometry: instrumentation and applications in forensics, chemistry, and biology

Ismael Cotte-Rodríguez et al. Anal Chem. .

Abstract

Ambient surfaces are examined by mass spectrometry at distances of up to 3 m from the instrument without any prior sample preparation. Non-proximate versions of the desorption electrospray ionization (DESI) and desorption atmospheric pressure chemical ionization experiments are shown to allow rapid, sensitive, and selective detection of trace amounts of active ingredients in pharmaceutical drug formulations, illicit drugs (methamphetamine, cocaine, and diacetylmorphine), organic salts, peptides, chemical warfare agent simulants, and other small organic compounds. Utilizing an ion transport tube to transport analyte ions to the mass spectrometer, nonproximate DESI allows one to collect high-quality, largely interference-free spectra with signal-to-noise (S/N) ratios of more than 100. High selectivity is achieved by tandem mass spectrometry and by reactive DESI, a variant experiment in which reagents added into the solvent spray allow bond-forming reactions with the analyte. Ion/molecule reactions were found to selectively suppress the response of mixture components other than the analyte of interest in nonproximate-DESI. Flexible ion transport tubing is also investigated, allowing performance similar to stainless steel tubing in the transport of ions from the sample to the mass spectrometer. Transfer tube temperature effects are examined. A multiple sprayer DESI source capable of analyzing a larger sample area was evaluated to decrease the sampling time and increase sample throughput. Low nanogram detection limits were obtained for the compounds studied from a wide variety of surfaces, even those present in complex matrixes.