The role of quantitative Schlieren assessment of physiotherapy ultrasound fields in describing variations between tissue heating rates of different transducers
- PMID: 17698281
- DOI: 10.1016/j.ultrasmedbio.2007.06.012
The role of quantitative Schlieren assessment of physiotherapy ultrasound fields in describing variations between tissue heating rates of different transducers
Abstract
Differences in tissue heating rates between ultrasound transducers have been well documented; however, comparative analysis between ultrasound fields to determine why tissue heating rates may differ is lacking. We selected three transducers from the same manufacturer with similar effective radiating area, output power, effective intensity and beam nonuniformity ratio [as defined by the FDA, 21 CFR Chap. 1, part 1,050 (10)], but markedly different Schlieren images. Each transducer was utilized to heat tissue with a standardized ultrasound application to determine whether Schlieren analysis may be useful in understanding variability in tissue heating rates. Thermocouples were inserted into the left triceps surae of 12 volunteers at a depth of 1.5 cm below one half the measured skin fold thickness (estimated average depth of the thermocouple was 1.99 +/- 0.27 cm). Each subject received one treatment from each transducer in a single session (n = 3); 3 MHz at 1.2 W/cm(2) for 8 min with a 100% duty cycle. Each transducer increased the IM temperature over time (p < 0.0001). IM temperatures were not significantly different between transducers from time zero to the fourth minute of treatment. After the fourth min, transducers B and C generated significantly higher tissue temperatures (p < 0.01). Transducer A, B and C increased IM temperature from 34.9 +/- 0.5 to 41.2 +/- 1.3 degrees C, 34.9 +/- 0.6 to 42.5 +/- 1.4 degrees C and 34.9 +/- 0.5 to 42.7 +/- 1.7 degrees C, respectively. Interestingly, transducer C emitted 22% lower output power but heated 24% higher than transducer A and our Schlieren images demonstrate that transducers B and C produced a more concentrated field compared with transducer A. The data we present here supports the general contention that a more concentrated field will heat to a higher temperature than a more disperse field, however, technical challenges in estimating output power, ERA and Schlieren analysis remain an issue.
Similar articles
-
Comparison of tissue heating between manual and hands-free ultrasound techniques.Physiother Theory Pract. 2010 Feb;26(2):100-6. doi: 10.3109/09593980802678315. Physiother Theory Pract. 2010. PMID: 20067359
-
Analysis of effective radiating area, power, intensity, and field characteristics of ultrasound transducers.Arch Phys Med Rehabil. 2007 Jan;88(1):124-9. doi: 10.1016/j.apmr.2006.09.016. Arch Phys Med Rehabil. 2007. PMID: 17207688
-
Variability in effective radiating area at 1 MHz affects ultrasound treatment intensity.Phys Ther. 2008 Jan;88(1):50-7. doi: 10.2522/ptj.20060358. Epub 2007 Oct 16. Phys Ther. 2008. PMID: 17940107
-
Advanced ultrasonic techniques for local tumor hyperthermia.Radiol Clin North Am. 1989 May;27(3):559-75. Radiol Clin North Am. 1989. PMID: 2648459 Review.
-
Implications of clinical RF hyperthermia on protection limits in the RF range.Health Phys. 2007 Jun;92(6):565-73. doi: 10.1097/01.HP.0000258918.36430.a3. Health Phys. 2007. PMID: 17495657 Review.
Cited by
-
Revealing physical interactions of ultrasound waves with the body through photoelasticity imaging.Opt Lasers Eng. 2024 Oct;181:108361. doi: 10.1016/j.optlaseng.2024.108361. Epub 2024 Jun 14. Opt Lasers Eng. 2024. PMID: 39219742
-
Therapeutic ultrasound as a potential male contraceptive: power, frequency and temperature required to deplete rat testes of meiotic cells and epididymides of sperm determined using a commercially available system.Reprod Biol Endocrinol. 2012 Jan 30;10:7. doi: 10.1186/1477-7827-10-7. Reprod Biol Endocrinol. 2012. PMID: 22289508 Free PMC article.
-
Short-term sensory and cutaneous vascular responses to therapeutic ultrasound in the forearms of healthy volunteers.J Ther Ultrasound. 2014 Jun 2;2:10. doi: 10.1186/2050-5736-2-10. eCollection 2014. J Ther Ultrasound. 2014. PMID: 24936304 Free PMC article.
-
Experimental Verification of Modeled Thermal Distribution Produced by a Piston Source in Physiotherapy Ultrasound.Biomed Res Int. 2016;2016:5484735. doi: 10.1155/2016/5484735. Epub 2016 Nov 23. Biomed Res Int. 2016. PMID: 27999801 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources