Prognostic value of very low plasma concentrations of troponin T in patients with stable chronic heart failure
- PMID: 17698733
- DOI: 10.1161/CIRCULATIONAHA.106.655076
Prognostic value of very low plasma concentrations of troponin T in patients with stable chronic heart failure
Abstract
Background: Circulating cardiac troponin T, a marker of cardiomyocyte injury, predicts adverse outcome in patients with heart failure (HF) but is detectable in only a small fraction of those with chronic stable HF. We assessed the prognostic value of circulating cardiac troponin T in patients with stable chronic HF with a traditional (cTnT) and a new precommercial highly sensitive assay (hsTnT).
Methods and results: Plasma troponin T was measured in 4053 patients with chronic HF enrolled in the Valsartan Heart Failure Trial (Val-HeFT). Troponin T was detectable in 10.4% of the population with the cTnT assay (detection limit < or = 0.01 ng/mL) compared with 92.0% with the new hsTnT assay (< or = 0.001 ng/mL). Patients with cTnT elevation or with hsTnT above the median (0.012 ng/mL) had more severe HF and worse outcome. In Cox proportional hazards models adjusting for clinical risk factors, cTnT was associated with death (780 events; hazard ratio=2.08; 95% confidence interval, 1.72 to 2.52; P<0.0001) and first hospitalization for HF (655 events; hazard ratio=1.55; 95% confidence interval, 1.25 to 1.93; P<0.0001). HsTnT was associated with the risk of death in unadjusted analysis for deciles of concentrations and in multivariable models (hazard ratio=1.05; 95% confidence interval, 1.04 to 1.07 for increments of 0.01 ng/mL; P<0.0001). Addition of hsTnT to well-calibrated models adjusted for clinical risk factors, with or without brain natriuretic peptide, significantly improved prognostic discrimination (C-index, P<0.0001 for both outcomes).
Conclusions: In this large population of patients with HF, detectable cTnT predicts adverse outcomes in chronic HF. By the highly sensitive assay, troponin T retains a prognostic value at previously undetectable concentrations.
Comment in
-
Significance of circulating troponins in heart failure: if these walls could talk.Circulation. 2007 Sep 11;116(11):1217-20. doi: 10.1161/CIRCULATIONAHA.107.721845. Circulation. 2007. PMID: 17846340 No abstract available.
Similar articles
-
Serial measurement of cardiac troponin T using a highly sensitive assay in patients with chronic heart failure: data from 2 large randomized clinical trials.Circulation. 2012 Jan 17;125(2):280-8. doi: 10.1161/CIRCULATIONAHA.111.044149. Epub 2011 Dec 2. Circulation. 2012. PMID: 22139751 Clinical Trial.
-
Prognostic use of cardiac troponin T and troponin I in patients with heart failure.Can J Cardiol. 2003 Mar 31;19(4):383-6. Can J Cardiol. 2003. PMID: 12704483
-
Serial biomarker measurements in ambulatory patients with chronic heart failure: the importance of change over time.Circulation. 2007 Jul 17;116(3):249-57. doi: 10.1161/CIRCULATIONAHA.107.694562. Epub 2007 Jun 25. Circulation. 2007. PMID: 17592074
-
Troponin elevation in heart failure prevalence, mechanisms, and clinical implications.J Am Coll Cardiol. 2010 Sep 28;56(14):1071-8. doi: 10.1016/j.jacc.2010.06.016. J Am Coll Cardiol. 2010. PMID: 20863950 Review.
-
Prognostic Value of High-Sensitivity Troponin T in Chronic Heart Failure: An Individual Patient Data Meta-Analysis.Circulation. 2018 Jan 16;137(3):286-297. doi: 10.1161/CIRCULATIONAHA.117.031560. Circulation. 2018. PMID: 29335288
Cited by
-
Prognostic value of highly sensitive troponin T on cardiac events in patients with chronic kidney disease not on dialysis.Heart Vessels. 2013 Jul;28(4):473-9. doi: 10.1007/s00380-012-0273-2. Epub 2012 Aug 23. Heart Vessels. 2013. PMID: 22914904
-
Factors affecting high-sensitivity cardiac troponin T elevation in Japanese metabolic syndrome patients.Diabetes Metab Syndr Obes. 2015 Mar 10;8:157-62. doi: 10.2147/DMSO.S80907. eCollection 2015. Diabetes Metab Syndr Obes. 2015. PMID: 25792848 Free PMC article.
-
Cardiac troponin T measured by a highly sensitive assay predicts coronary heart disease, heart failure, and mortality in the Atherosclerosis Risk in Communities Study.Circulation. 2011 Apr 5;123(13):1367-76. doi: 10.1161/CIRCULATIONAHA.110.005264. Epub 2011 Mar 21. Circulation. 2011. PMID: 21422391 Free PMC article.
-
Detection of acute changes in circulating troponin in the setting of transient stress test-induced myocardial ischaemia using an ultrasensitive assay: results from TIMI 35.Eur Heart J. 2009 Jan;30(2):162-9. doi: 10.1093/eurheartj/ehn504. Epub 2008 Nov 8. Eur Heart J. 2009. PMID: 18997177 Free PMC article.
-
Bench-to-bedside review: the value of cardiac biomarkers in the intensive care patient.Crit Care. 2008;12(3):215. doi: 10.1186/cc6880. Epub 2008 Jun 2. Crit Care. 2008. PMID: 18557993 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous