Temperature change, dentinal fluid flow and cuspal displacement during resin composite restoration
- PMID: 17716269
- DOI: 10.1111/j.1365-2842.2007.01764.x
Temperature change, dentinal fluid flow and cuspal displacement during resin composite restoration
Abstract
Dentin-bonding agents and resin composite materials typically require light activation for polymerization. Light curing generates heat, which may influence dentinal fluid flow (DFF) and cuspal displacement. This study investigated the relationship among temperature increase, DFF and cuspal displacement in extracted human maxillary premolars with a mesial occlusal distal (MOD) cavity preparation. Two types of curing light were compared. Temperature changes were measured using thermocouples located on the occlusal cavity floor and at the pulp-dentine junction, during polymerization of bonding agent and resin composite material. DFF and cuspal displacement were measured simultaneously using automated flow measurement apparatus and direct current differential transformers respectively. Temperature increases of up to 15 degrees C were recorded during the restoration procedures. A quartz tungsten halogen (QTH) unit produced a significantly greater temperature increase than a light-emitting diode unit and curing of the bonding agent generated less temperature increase than curing of the resin composite. Heating due to exothermic reaction during polymerization of bonding agent and resin was not significantly different between light sources or between bonding and curing (P > 0.05). The QTH unit produced both greater inward fluid flow and cuspal displacement during the irradiation of bonding agent and resin composite than the light-emitting diode unit. There was not a simple relationship between temperature increase, fluid movement and cuspal displacement. From a clinical point of view, the light-emitting diode unit can be considered preferable to the QTH light, because it caused significantly smaller temperature increase, fluid shift and cuspal displacement.
Similar articles
-
Dentinal fluid flow and cuspal displacement in response to resin composite restorative procedures.Dent Mater. 2007 Nov;23(11):1405-11. doi: 10.1016/j.dental.2006.11.029. Epub 2007 Feb 12. Dent Mater. 2007. PMID: 17296218
-
Effect of different modes of light curing and resin composites on microleakage of Class II restorations.Odontostomatol Trop. 2008 Dec;31(124):27-34. Odontostomatol Trop. 2008. PMID: 19441264 Clinical Trial.
-
Temperature rise in the pulp chamber induced by a conventional halogen light-curing source and a plasma arc lamp.Am J Dent. 2004 Jun;17(3):203-8. Am J Dent. 2004. PMID: 15301219
-
A rational use of dental materials in posterior direct resin restorations in order to control polymerization shrinkage stress.Minerva Stomatol. 2007 Mar;56(3):129-38. Minerva Stomatol. 2007. PMID: 17327817 Review.
-
Resin pins: a novel composite resin concept for treatment of posterior teeth--technical presentation.Pract Proced Aesthet Dent. 2008 Sep;20(8):507-11; quiz 512. Pract Proced Aesthet Dent. 2008. PMID: 18990903 Review.
Cited by
-
Temperature changes under demineralized dentin during polymerization of three resin-based restorative materials using QTH and LED units.Restor Dent Endod. 2014 Aug;39(3):155-63. doi: 10.5395/rde.2014.39.3.155. Epub 2014 May 13. Restor Dent Endod. 2014. PMID: 25110638 Free PMC article.
-
The effects of extended curing time and radiant energy on microhardness and temperature rise of conventional and bulk-fill resin composites.Clin Oral Investig. 2019 Oct;23(10):3777-3788. doi: 10.1007/s00784-019-02807-1. Epub 2019 Jan 28. Clin Oral Investig. 2019. PMID: 30693403
-
Comparison of temperature change among different adhesive resin cement during polymerization process.J Indian Prosthodont Soc. 2017 Apr-Jun;17(2):183-188. doi: 10.4103/jips.jips_327_16. J Indian Prosthodont Soc. 2017. PMID: 28584420 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources