Mapping of error cells in clinical measure to symmetric power space
- PMID: 17718888
- DOI: 10.1111/j.1475-1313.2007.00505.x
Mapping of error cells in clinical measure to symmetric power space
Abstract
During the refraction procedure, the power of the nearest equivalent sphere lens, known as the scalar power, is conserved within upper and lower bounds in the sphere (and cylinder) lens powers. Bounds are brought closer together while keeping the circle of least confusion on the retina. The sphere and cylinder powers and changes in these powers are thus dependent. Changes are depicted in the cylinder-sphere plane by error cells with one pair of parallel sides of negative gradient and the other pair aligned with the graph axis of cylinder power. Scalar power constitutes a vector space, is a meaningful ophthalmic quantity and is represented by the semi-trace of the dioptric power matrix. The purpose of this article is to map to error cells for the following: coordinates of the dioptric power matrix, its principal powers and meridians and its entries from error cells surrounding powers in sphere, cylinder and axis. Error cells in clinical measure for conserved scalar power now contain more compensatory lens powers. Such cells and their respective mappings in terms of most scientific and alternate clinical quantities now image consistently not only to the cells from where they originate but also to each other.
Similar articles
-
Isomorphism and possible invariance of error cells under spherocylindrical transposition.Optom Vis Sci. 2007 May;84(5):443-51. doi: 10.1097/OPX.0b013e31804f5adf. Optom Vis Sci. 2007. PMID: 17502829
-
Tolerance and nature of residual refraction in symmetric power space as principal lens powers and meridians change.Comput Math Methods Med. 2014;2014:492383. doi: 10.1155/2014/492383. Epub 2014 Nov 12. Comput Math Methods Med. 2014. PMID: 25478004 Free PMC article.
-
Revisions to tolerances in cylinder axis and in progressive addition lens power in ANSI Z80.1-2005.Optometry. 2006 Jul;77(7):343-9. doi: 10.1016/j.optm.2006.04.108. Optometry. 2006. PMID: 16814238 Review.
-
Error cells for spherical powers in symmetric dioptric power space.Optom Vis Sci. 2005 Jul;82(7):633-6. doi: 10.1097/01.opx.0000171353.54199.43. Optom Vis Sci. 2005. PMID: 16044077
-
Dioptric power: its nature and its representation in three- and four-dimensional space.Optom Vis Sci. 1997 Jun;74(6):349-66. doi: 10.1097/00006324-199706000-00018. Optom Vis Sci. 1997. PMID: 9255813 Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical