Ten-year air sample analysis of Aspergillus prevalence in a university hospital
- PMID: 17719681
- DOI: 10.1016/j.jhin.2007.06.008
Ten-year air sample analysis of Aspergillus prevalence in a university hospital
Abstract
Airborne fungal samples were collected on a monthly basis for 10 years, from 1995 to 2005, at a tertiary university hospital. Paired samples were cultured at 25 and 37 degrees C. Data were interpreted according to the air filtration systems serving each location. Samples cultured at 37 degrees C from the patient care areas had a mean recovery of 18% of the mean recovery from outdoor air (22 versus 122cfu/m(3)). Recovery of Aspergillus spp. at 37 degrees C in the high-efficiency particulate air (HEPA)-filtered locations was positive for Aspergillus spp. approximately one-third of the time; the rest of the patient care areas were positive half of the time and the outdoor samples were positive 95% of the time. We found 48 sporadic bursts at 37 degrees C which produced counts >3 SD above the mean. Hospital-acquired infection was related to high recovery of Aspergillus fumigatus on at least one occasion. We have found it impossible, without implementing impractical measures, to provide an environment completely devoid of Aspergillus spp. We conclude that routine air sampling is not an effective means of predicting hospital-acquired infections. However, a transient spike, or burst, may be useful in identifying an in-house source of contamination and may be used to consider additional interventional treatments for patients at risk. Emphasis should be placed on maintaining high-efficiency filtration of the outside air and on ensuring that other environmental control methods are used to prevent dissemination of environmental opportunistic fungal spores.
Comment in
-
Routine sampling of air for fungi does not predict risk of invasive aspergillosis in immunocompromised patients.J Hosp Infect. 2008 Mar;68(3):270-1. doi: 10.1016/j.jhin.2007.11.017. Epub 2008 Jan 15. J Hosp Infect. 2008. PMID: 18226417 No abstract available.
-
Air quality monitoring of HEPA-filtered hospital rooms by particulate counting.J Hosp Infect. 2009 Apr;71(4):387-8. doi: 10.1016/j.jhin.2008.10.023. Epub 2008 Dec 5. J Hosp Infect. 2009. PMID: 19058877 No abstract available.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous