Carbon nanotubes and glucose oxidase bionanocomposite bridged by ionic liquid-like unit: preparation and electrochemical properties
- PMID: 17720471
- DOI: 10.1016/j.bios.2007.06.010
Carbon nanotubes and glucose oxidase bionanocomposite bridged by ionic liquid-like unit: preparation and electrochemical properties
Abstract
For their biocompatibility and potential bionanoelectronic applications, integration of carbon nanotubes (CNTs) with biomolecules such as redox enzyme is highly anticipated. Therein, CNTs are expected to act not only as an electron transfer promoter, but also as immobilizing substrate for biomolecules. In this report, a novel method for immobilization of biomolecules on CNTs was proposed based on ionic interaction, which is of universality and widespread use in biological system. As illustrated, glucose oxidase (GOD) and single-walled carbon nanotubes (SWNTs) were integrated into a unitary bionanocomposite by means of ionic liquid-like unit on functionalized SWNTs. The resulted bionanocomposite illustrated better redox response of immobilized GOD in comparison of that prepared by weak physical absorption without ionic interaction. As a potential application of concept, the electrochemical detection of glucose was exemplified based on this novel bionanocomposite.
Similar articles
-
Direct electrochemistry of glucose oxidase and electrochemical biosensing of glucose on quantum dots/carbon nanotubes electrodes.Biosens Bioelectron. 2007 Jun 15;22(12):3203-9. doi: 10.1016/j.bios.2007.02.013. Epub 2007 Mar 1. Biosens Bioelectron. 2007. PMID: 17416515
-
Polymerized ionic liquid-wrapped carbon nanotubes: the promising composites for direct electrochemistry and biosensing of redox protein.Talanta. 2010 Mar 15;80(5):1719-24. doi: 10.1016/j.talanta.2009.10.012. Epub 2009 Oct 14. Talanta. 2010. PMID: 20152402
-
Preparation of gold nanoparticles/functionalized multiwalled carbon nanotube nanocomposites and its glucose biosensing application.Biosens Bioelectron. 2009 Feb 15;24(6):1765-70. doi: 10.1016/j.bios.2008.09.005. Epub 2008 Sep 18. Biosens Bioelectron. 2009. PMID: 18951009
-
Review: Carbon nanotube based electrochemical sensors for biomolecules.Anal Chim Acta. 2010 Mar 10;662(2):105-27. doi: 10.1016/j.aca.2010.01.009. Epub 2010 Jan 11. Anal Chim Acta. 2010. PMID: 20171310 Review.
-
Carbon nanotubes for electrochemical biosensing.Talanta. 2007 Dec 15;74(3):291-307. doi: 10.1016/j.talanta.2007.10.013. Epub 2007 Oct 16. Talanta. 2007. PMID: 18371643 Review.
Cited by
-
Cross-linked glucose oxidase clusters for biofuel cell anode catalysts.Biofabrication. 2013 Sep;5(3):035009. doi: 10.1088/1758-5082/5/3/035009. Epub 2013 Jul 23. Biofabrication. 2013. PMID: 23880606 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials